The pressure reduction coefficient: A new parameter to assess aneurysmal blood stasis induced by flow diverters/disruptors

Author:

Gascou Gregory1,Ferrara Riccardo2,Ambard Dominique2,Sanchez Mathieu2,Lobotesis Kyriakos3,Jourdan Franck2,Costalat Vincent1

Affiliation:

1. Department of Neuroradiology, CHU Gui de Chauliac, Montpellier, France

2. Laboratoire de mécanique et de génie civil, Universite de Montpellier, Montpellier, France

3. Charing Cross Hospital, Imperial College Hospitals, NHS Trust, London, UK

Abstract

Background and purpose Pore density (PD), surface metal coverage (SMC) and the number of wires are all different parameters which can influence the efficacy of a flow disruptor/diverter. Nevertheless, the relative importance of a parameter to induce intra-aneurysmal blood stasis is still poorly evaluated. Therefore, comparison between devices based on a unique value is not reliable. The aim of this study was to propose a new bench top parameter (the pressure reduction coefficient (PRC; ξ)) in order to assess the global haemodynamic effect of each flow diverter/disruptor to slow flow. Methods Eight devices were tested in vitro during three different flow conditions. For the eight devices, the PRC was computed at different volumetric flow rates to characterise flow reduction. Comparison was made with SMC, PD and the number of wires. Results The PRC obtained for flow disruptors was on average 1.5 times more efficient in reducing flow compared to flow diverters. PD (mm2) ranged from 24 to 38 for flow diverters and did not independently correlate with the PRC. The SMC of flow diverters ranged from 25% to 70%, and ranged from 20% to 100% for flow disruptors, without independent correlation to the PRC. The number of wires ranged from 48 to 96 for the flow diverters and did not correlate independently to the PRC. Conclusion There were no direct correlations between individual device characteristics and the PRC, suggesting a multifaceted and interrelating association of the overall design of each implant. Hence, the PRC could be used as a simple, reliable parameter to assess the overall capacity of flow disruptors/diverters to induce intra-aneurysmal blood stasis.

Publisher

SAGE Publications

Subject

Immunology

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370