Utility of quantitative magnetic resonance angiography and non-invasive optimal vessel analysis for identification of complications and long-term hemodynamic changes in post-pipeline embolization patients

Author:

Ryu Brendan1ORCID,White Timothy G1ORCID,Shah Kevin A1ORCID,Turpin Justin1ORCID,Link Thomas1,Dehdashti Amir R1,Katz Jeffrey M2,Black Karen3,Woo Henry H1

Affiliation:

1. Department of Neurosurgery, Donald and Barbara Zucker School of Medicine at Hofstra/Northwell, Manhasset, NY, USA

2. Department of Neurology, Donald and Barbara Zucker School of Medicine at Hofstra Northwell, Manhasset, NY, USA

3. Department of Radiology, Donald and Barbara Zucker School of Medicine at Hofstra Northwell, Manhasset, NY, USA

Abstract

Introduction Quantitative magnetic resonance angiography and non-invasive optimal vessel analysis serve as powerful tools to collect and analyze hemodynamic data from pipeline embolization patients. At our institution, patients receive post-embolization quantitative magnetic resonance angiography within 24 h of treatment and within 6 months for follow-up to evaluate pipeline patency. Here, we aim to elucidate the long-term hemodynamic changes following pipeline embolization device placement and report two cases in which in-stent stenosis was detected. Methods Medical records of patients who underwent pipeline embolization device placement for an internal carotid artery aneurysm between 2017 and 2019 were reviewed. Patients who received post-procedure NOVA and follow-up NOVA were included in the study ( n = 32). Location and size of aneurysm, number of pipeline embolization device deployed, and complications were collected along with the non-invasive optimal vessel analysis report (flow volume rate (ml/min), mean, systolic, and diastolic flow velocities (cm/s), and vessel diameter (mm)). Internal carotid artery vessel flow rate was measured proximal to the pipeline embolization device. Derivations of hemodynamic parameters (pulsatility index, Lindegaard ratio, and wall shear stress) were calculated. Results The middle cerebral artery mean and diastolic flow velocities were significantly lower on the follow-up NOVA compared to the post-procedure NOVA. Moreover, follow-up NOVA demonstrated lower middle cerebral artery wall shear stress on the side with flow diversion compared to the post-procedure NOVA. In-stent stenosis, requiring intervention, was detected in two patients on follow-up NOVA. One patient had a successful balloon angioplasty of the stented internal carotid artery that resolved her stenosis. However, the second patient developed progressive stenosis and expired despite intervention. Conclusion Long-term hemodynamic adaptations post-pipeline embolization device demonstrate decreased wall shear stress and decreased mean and diastolic flow velocities in the distal middle cerebral artery, which suggest decreasing velocity of blood flow with endothelialization of the device. Furthermore, follow-up NOVA is a useful tool for detecting potential flow-related complications such as in-stent stenosis.

Publisher

SAGE Publications

Subject

Immunology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Antiplatelets/ticagrelor;Reactions Weekly;2022-10-29

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3