5-Year Angiographic and Clinical Follow-up of Coil-Embolised Intradural Saccular Aneurysms

Author:

Batista LL1,Mahadevan J.1,Sachet M.1,Alvarez H.1,Rodesch G.1,Lasjaunias P.1

Affiliation:

1. Service de Neuroradiologie Vasculaire Diagnostique et Thérapeutique, CHU de Bicêtre, Le Kremlin-Bicêtre; France

Abstract

The purpose of the paper is the follow-up of embolised intradural saccular Arterial Aneurysms (AA), excluding giant, dissecting, inflammatory, fusiform or AA associated to BVAM. Since its introduction in 1991, the Guglielmi Detachable Coil has offered protection against aneurysmal rebleeding in the critical few days and months after SAH regardless of the grade. A number of questions remain: is complete angiographic obliteration necessary at first embolisation? What duration of clinical / angiographic follow-up (FU) is required to ensure the risk of haemorrhage has been eliminated? What is the long-term protection against rebleeding? One hundred and two patients with 160 intradural saccular AA embolised before april 1997 were selected for this study. They had at least 5-yrs clinical FU, of which 22 patients had a mid-term (3 years) and 45 patients had a 5-year or more angiographic FU (mean 67,7 months per patient). Twenty-eight embolised AAs with 100% occlusion at 1 year, remained unchanged on the 5-year angiograms. A further 14 patients with complete occlusion at 1 year showed persisting complete occlusion on angiogram at 3-years FU, which in our series means that complete occlusion after the first year post-embolisation implies that the aneurysm will remain completely occluded. All secondary spontaneous thromboses (27.6% of cases), occurred during the first year pos-embolisation. In six patients with subtotal or partial occlusion no change was seen for three consecutive years of FU; none showed later change at 5-year angiography. Below 80% occlusion our series does not provide enough information but we consider the situation instable. No mortality related to the procedure was observed in the unruptured AA group. No bleeding or re-bleeding has occurred since the beginning of our experience (1993) in saccular AA treated by GDC-Coil. Coil-embolisation of properly selected patients is effective in protecting against bleeding or re-bleeding at short and long-term with stable morphological results provided a strict follow-up control is established at short term.

Publisher

SAGE Publications

Subject

Immunology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3