In vitro testing of a funnel-tip catheter with different clot types to decrease clot migration in mechanical thrombectomy

Author:

Payne Emily S.1ORCID,Krost-Reuhl Samantha1,Heimann Axel2,Keric Naureen3,Masomi-Bornwasser Julia3ORCID,Gerber Tiemo4,Seidman Larissa4,Kirschner Stefanie5,Brockmann Marc A.1,Tanyildizi Yasemin1

Affiliation:

1. Department of Neuroradiology, University Medical Center of the Johannes Gutenberg University, Mainz, Germany

2. Translational Animal Research Center, University Medical Center, Mainz, Germany

3. Department of Neurosurgery, University Medical Center, Mainz, Germany

4. Institute of Pathology, University Medical Center, Mainz, Germany

5. Department of Radiation Oncology, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany

Abstract

Background Mechanical thrombectomy is the standard treatment for acute ischemic stroke in patients with large vessel occlusion and can be performed up to 24h after symptom onset. Despite high recanalization rates, embolism in new territories has been reported in 8.6% of the cases. Causes for this could be clot abruption during stent retrieval into the smaller opening of a standard distal access catheter, and antegrade blood flow via collaterals despite proximal balloon protection. A funnel-shaped tip with a larger internal diameter was developed to increase the rate of first-pass recanalization and to improve the safety and efficacy of mechanical thrombectomy. Methods This in vitro study compared the efficacy of a funnel-shaped tip with a standard tip in combination with different clot compositions. Mechanical thrombectomy was performed 80 times for each tip, using two stent retrievers (Trevo XP ProVue 3/20 mm, 4/20 mm) and four different clot types (hard vs. soft clots, 0–24h vs. 72h aged clots). Results Significantly higher first-pass recanalization rates (mTICI 3) were observed for the funnel-shaped tip, 70.0% versus 30.0% for the standard tip (absolute difference, 32; relative difference 57.1%; P < .001), regardless of the clot type and stent retriever. Recanalization could be increased using harder Chandler loop clots versus softer statically generated clots, as well as 0–24h versus 72h aged clots, respectively. Conclusion The funnel-shaped tip achieved higher first-pass recanalization rates than the smaller standard tip and lower rates of clot abruption at the tip. Clot compositions and aging times impacted recanalization rates.

Funder

Bundesministerium für Wirtschaft und Energie

Publisher

SAGE Publications

Subject

Immunology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3