Retrograde three-dimensional rotational angiography: A novel method for the detection of plaque protrusion during carotid artery stenting under continuous distal balloon protection

Author:

Hosoo Hisayuki1ORCID,Tsuruta Wataro1,Hamada Yusuke2,Katsumata Masahiro1,Ishigami Daiichiro1,Ishikawa Eiichi3,Matsumaru Yuji4,Matsumura Akira3

Affiliation:

1. Department of Endovascular Neurosurgery, Toranomon Hospital, Tokyo, Japan

2. Department of Radiological Technology, Toranomon Hospital, Tokyo, Japan

3. Department of Neurosurgery, Faculty of Medicine, University of Tsukuba, Ibaraki, Japan

4. Division of Stroke Prevention and Treatment, Department of Neurosurgery, Faculty of Medicine, University of Tsukuba, Ibaraki, Japan

Abstract

Background To prevent ischemic complications during carotid artery stenting, accurate detection of plaque protrusion and appropriate additional treatment are essential. Here, we introduce a novel method for the detection of plaque protrusion under distal balloon protection using three-dimensional rotation angiography—“retrograde 3DRA.” We evaluated the safety and efficacy of this method. Materials and methods We retrospectively analyzed 28 consecutive carotid artery stenting procedures under distal balloon protection at our hospital between July 2017 and August 2019. The first line of protection was dual balloon protection (proximal and distal balloon). After stent deployment, balloon dilatation, and subsequent blood aspiration, 3DRA was performed with the injection of diluted contrast medium from the aspiration catheter positioned just proximal to the distal protection balloon. The stent lumen was analyzed by obtaining the reconstruction maximum intensity projection image. Results Among the 28 cases, all cases could be assessed for in-stent plaque protrusion using “retrograde 3DRA.” We were able to evaluate the stent lumen clearly. There were three cases (10.7%) in which plaque protrusion could be confirmed. Since additional balloon dilatation was performed for all protrusion cases under continuing balloon protection, no ischemic complications occurred. Conclusion Retrograde 3DRA could be safe and useful for the detection of plaque protrusions and to avoid ischemic complication for tolerable cases of internal carotid artery transient balloon protection.

Publisher

SAGE Publications

Subject

Immunology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3