Efficacy and safety of PulseRider for treatment of wide-necked intracranial aneurysm—A systematic review and meta-analysis

Author:

Pranata Raymond1ORCID,Yonas Emir2,Vania Rachel1,Sidipratomo Prijo3,July Julius45

Affiliation:

1. Faculty of Medicine, Universitas Pelita Harapan, Tangerang, Indonesia

2. Faculty of Medicine, Universitas YARSI, Jakarta, Indonesia

3. Department of Radiology, Faculty of Medicine, Universitas Indonesia, Dr. Cipto Mangunkusumo Hospital, Jakarta, Indonesia

4. Department of Neurosurgery, Medical Faculty, Pelita Harapan University, Tangerang, Indonesia

5. Neuroscience Centre Siloam Hospital, Tangerang, Indonesia

Abstract

Objective PulseRider is a novel self-expanding nickel-titanium (nitinol) stent for treatment of wide-necked aneurysms, which is commonly located at the arterial branches in the brain. This systematic review and meta-analysis aims to assess the efficacy and safety of PulseRider for treatment of wide-necked intracranial aneurysm. Method We performed a systematic literature search on articles that evaluate the efficacy and safety of PulseRider-assisted coiling of the wide-necked aneurysm from several electronic databases. The primary endpoint was adequate occlusion, defined as Raymond-Roy Class I + Raymond-Roy Class II upon immediate angiography and at six-month follow-up. Results There were a total of 157 subjects from six studies. The rate of adequate occlusion on immediate angiography was 90% (95% CI, 85%–94%) and 91% (95% CI, 85%–96%) at six-month follow-up. Of these, Raymond-Roy Class I can be observed in 48% (95% CI, 41%–56%) of aneurysms immediately after coiling, and 64% (95% CI, 55%–72%) of aneurysms on six-month follow-up. Raymond-Roy Class II was found in 30% (95% CI, 23%–37%) of aneurysms immediately after coiling, and 25% (17–33) after six-month follow-up. Complications occur in 5% (95% CI, 1%–8%) of the patients. There were three intraoperative aneurysm rupture, three thrombus formation, three procedure-related posterior cerebral artery strokes, one vessel dissection, and one delayed device thrombosis. There was no procedure/device-related death. Conclusions PulseRider-assisted coiling for treatment of patients with wide-necked aneurysm reached 90% adequate occlusion rate that rises up to 91% at sixth month with 5% complication rate.

Publisher

SAGE Publications

Subject

Immunology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370