Treatment and Short-Term Follow-up of Symptomatic Atherosclerotic Intracranial Artery Stenosis by Stent-Assisted Angioplasty

Author:

Feng Miao Zhongrong Ling1,Shengmao Li,Fengshui Zhu,Yang Hua,Moli Wang

Affiliation:

1. Department of Neurosurgery, Capital University of Medical Science (CUMS)

Abstract

Atherosclerotic intracranial artery stenosis can cause hypoperfusion of brain tissues and embolus formation, causing stroke. Conservative medical treatment seemed to have little effect on the natural history and prevent the stroke attack caused by artery stenosis. The purpose of stent-assisted angioplasty is to reconstruct the damaged vessels: the indications, feasibility, effectiveness, complications and follow-up for this new treatment method are discussed. A series of 32 cases with symptomatic intracranial artery stenosis were accepted from 1998 to 2002. The mean age was 42 yrs (31∼76 yr), male/female ratio=23/9. All patients were refractory to optimal medical therapy. Lesions included 12 middle cerebral arteries (37.5%), six basilar arteries (18.75%), three distal ICAs (9.38%) and 12 intracranial Vas (37.5%). All patients were treated by methods of transluminal stent-assisted angioplasty under general anesthesia. Patients were premedicated with Aspirin (300mg/per day) and Ticlopidine (250mg/per day), this was continued for six weeks after the procedure. Medical history, anamnesis, and treatment protocol were reviewed and evaluated retrospectively, short-term follow-up (2mths ∼ 1 yr) was also obtained. Primary clinical presentations were TIAs (21/32, 65.63%), minor stroke (8/32, 25%) and severe stroke (3/32, 9.38%). 31 cases (96.86%) were successfully implanted with coronary stents within the stenosed vessels; technical success rate was 96.86%. Instant angiographic results showed the stenosed extent had decreased from 72.36%±5.69 to 10.16%±6.94. One vessel ruptured during the procedure, the patient recovered after surgical repair of the ruptured vessel. Clinical follow-up demonstrated symptoms resolved in most patients (30/32, 93.75%) within the follow-up period, two cases with MCA stenosis had TIAs within two months after the procedure. 12 cases accepted angiographic follow-up. Velocities of stented vessels of five cases (5/21, 23.81%) increased compared to instant results, suggesting restenosis, three of them were confirmed by angiography which included two cases with MCA stenosis (figure 3) and one with distal VA, one of the five cases had recurred TIAs. With the newer generation of coronary stent, this technique seemed safe, feasible and effective to prevent stroke attack, but the indication is very important for the technical success. Restenosis remains a common problem as with coronary stenting. Long-term follow-up will be needed.

Publisher

SAGE Publications

Subject

Immunology

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3