A 6-Fr Guiding Catheter (Slim Guide®) for Use with Multiple Microdevices

Author:

Kai Y.12,Ohmori Y.1,Watanabe M.3,Kaku Y.1,Morioka M.1,Hirano T.3,Yano S.1,Kawano T.1,Hamada J-I.4,Kuratsu J-I.1

Affiliation:

1. Department of Neurosurgery, Graduate School of Medical Sciences, Kumamoto University; Kumamoto, Japan

2. Department of Cerebrovascular Disease and Acute Coronary Syndrome, Graduate School of Medical Sciences, Kumamoto University; Kumamoto, Japan

3. Department of Neurology, Graduate School of Medical Sciences, Kumamoto University; Kumamoto, Japan

4. Department of Neurosurgery, Graduate School of Medical Sciences, Kanazawa University; Kanazawa, Japan

Abstract

A modified technique is required in patients with wide-necked aneurysms whose treatment by the single microcatheter technique is difficult. We developed a 6-Fr guiding catheter (Slim Guide®) that features a large lumen (0.072 inch) for performing the modified technique. To evaluate the usefulness of Slim Guide® we carried out experiments using three types of 6-Fr guiding catheter. In experiment 1, the shaft hardness and kink resistance were compared among three different guiding catheters (Slim Guide®, Launcher®, Envoy®). In experiment 2, we inserted a microballoon catheter and a microcatheter into the three different guiding catheters and recorded the maximal infusion pressure. In experiment 3, we inserted 13 different types of microdevices into the three different guiding catheters and evaluated the resistance of the microdevices. Although the shaft of the Slim Guide® was softer than that of the other two guiding catheters, its kink resistance was comparable. The maximal infusion pressure was significantly lower than with Launcher® or Envoy® catheters. Furthermore, with Slim Guide®, in 136 of 143 microdevice combinations examined (95.1%) there was no resistance; this was true for 125 (87.4%) and 116 (81.1%) combinations using the Launcher® - and the Envoy® guiding catheters, respectively. There was a significant difference between Slim Guide® and the other two guiding catheters with respect to their accommodation of double microsystems (p<0.05). Although the inner diameter of Slim Guide® is slightly larger than of the other two guiding catheters, it significantly increased the combination of microdevices that could be used for the coil embolization of difficult aneurysms.

Publisher

SAGE Publications

Subject

Immunology

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3