Quantitative magnetic resonance angiography to assess post embolization hemodynamics following pipeline embolization

Author:

White Timothy G1ORCID,Ryu Brendan1ORCID,Shah Kevin A1ORCID,Turpin Justin1ORCID,Black Karen2,Link Thomas1,Dehdashti Amir R1,Katz Jeffrey M3,Woo Henry H1

Affiliation:

1. Department of Neurosurgery, Donald and Barbara Zucker School of Medicine at Hofstra Northwell, US

2. Department of Radiology, Donald and Barbara Zucker School of Medicine at Hofstra Northwell, US

3. Department of Neurology, Donald and Barbara Zucker School of Medicine at Hofstra Northwell, US

Abstract

Introduction Delayed intraparenchymal hemorrhage is a known complication of the Pipeline Embolization device (PED); however, its etiology is unclear and some have suggested it is a flow related phenomenon. Quantitative magnetic resonance angiography (QMRA) serves as a powerful tool to collect and analyze hemodynamic data. We report a detailed characterization of short-term hemodynamics after PED placement. Methods Patients who underwent PED placement for a distal internal carotid artery (ICA) aneurysm between 2017 to 2019 with post embolization QMRA were reviewed. Aneurysm characteristics, flow volume rate (ml/min), mean, systolic, and diastolic flow velocities (cm/s), vessel diameter (mm), pulsatility index, Lindegaard ratio, and wall shear stress (WSS) were collected. Results A total of 67 patients were included. Post-procedure patients were found to have a significantly lower ICA flow on the side with flow diversion when compared to the side without flow diversion (218 vs. 236.3; P < 0.05). Average ICA flow after flow diversion for aneurysms >2 cm was significantly lower when compared to the untreated side (187.7 vs. 240.4; P < 0.05). There was no difference in MCA or ACA flow or velocity. WSS was significantly lower in the treated ICA (8.2 vs. 9.0; P < 0.05). Lindegaard ratio was not different in the treated vs. contralateral untreated sides. Conclusion PED placement for distal ICA aneurysms results in lower flow, mean velocity, and WSS when compared to the contralateral untreated ICA. This is not demonstrated distal to the Pipeline device in the ACA or MCA territories. Ultimately these findings suggest hemodynamic changes are not a cause of PED complications.

Publisher

SAGE Publications

Subject

Immunology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3