Three-dimensional rotational angiography improves mechanical thrombectomy recanalization rate for acute ischaemic stroke due to middle cerebral artery M2 segment occlusions

Author:

Rosi Andrea12ORCID,Bernava Gianmarco12ORCID,Hofmeister Jeremy12,Nicolò Madruzzato3,Boto José1,Yilmaz Hasan1,Reymond Philippe24,Brina Olivier12,Muster Michel12,Carrera Emmanuel5,Lövblad Karl-Olof1,Machi Paolo12

Affiliation:

1. Division of Diagnostic and Interventional Neuroradiology, Department of Diagnostics, Geneva University Hospitals, Geneva, Switzerland

2. Brain Endovascular Therapeutics Research and Development Laboratory, Radiology and Medical Informatics, University of Geneva, Geneva, Switzerland

3. Neuroradiology, Verona University Hospital, Verona, Italy

4. Departement of Surgery, Geneva University Hospitals, Geneva, Switzerland

5. Division of Neurology, Department of Neurosciences, Geneva University Hospitals, Geneva, Switzerland

Abstract

Background Occlusions of the middle cerebral artery (MCA) M2 segments can be difficult to address with mechanical thrombectomy (MTB) using standard projections and this can affect the final recanalization. Three-dimensional rotational angiography (3D-RA) allows to obtain a 3D model of cerebral vessels in a few seconds and to determine the best two-dimensional (2D) projections to be selected to evaluate and treat cerebrovascular diseases, such as aneurysms or vascular malformations. We aimed to determine if 3D-RA could be applied also in MTB. Methods A retrospective review of two patient cohorts treated during two time periods of 12 months before and after the introduction of 3D-RA use at our institution for MTB in M2 occlusions. Analyses were conducted to compare the two groups for procedural characteristics, such as timing, recanalization rate and complications and clinical outcome. Results One hundred acute ischaemic stroke (AIS) patients (3D-RA group = 57; controls = 43) underwent MTB for an M2 occlusion during the two study periods. Recanalization rates were significantly higher in cases treated with 3D-RA. The mean 3D technique thrombectomy time was compared to that of non-3D cases (47 vs. 49 min, respectively). Conclusions Our findings showed that 3D-RA is a useful tool to select specific working projections to AIS patients presenting an M2 occlusion by improving final recanalization compared to standard projections, without increasing the overall procedural time.

Funder

Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung

Publisher

SAGE Publications

Subject

Immunology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3