Accuracy of uncalibrated 2D digital subtraction angiography measurements on a novel biplane system compared to computed tomography angiography

Author:

Landström Lovisa12,Wasselius Johan A12

Affiliation:

1. Department of Medical Imaging and Physiology, Skåne University Hospital, Lund, Sweden

2. Department of Clinical Sciences, Lund University, Lund, Sweden

Abstract

Background 2D digital subtraction angiography (DSA) images are the gold standard for neuroradiological vascular assessment and the basis of interventional procedures such as mechanical thrombectomy and cerebral aneurysm coiling. However, length measurements in projected DSA images are affected by the distance between the x-ray source, the object, and the detector. Precise coordination between all integrated parts of a novel biplane system makes it possible to accurately measure DSA distances without manual calibration. The aim of this study was to compare vascular diameter measurements in uncalibrated DSA images with computed tomography angiography (CTA). Methods Consecutive patients undergoing interventional neuroradiological procedures were retrospectively included. Vascular diameter measurements in the image isocenter and periphery were performed. These measurements were repeated in picture archiving and communication system (PACS) on DSA images and maximum intensity pixel (MIP) CTA images. Results Forty-two (42) consecutive patients with adequate DSA and CTA images were included in the final analysis. The correlation between vessel diameter measurements in the image isocenter (R2 = 0.81/0.85, p < 0.0001/p < 0.0001 [Reader1/Reader2]), periphery (R2 = 0.85/0.82, p < 0.0001/p < 0.0001 [Reader1/Reader2]), and all measurements combined (R2 = 0.87/0.87, p < 0.0001/p < 0.0001 [Reader1/Reader2]) on DSA and CTA were strong and statistically significant. The interclass correlation coefficient for measurements performed by two independent reviewers was strong (ICC = 0.96, 95% CI 0.92–0.98). Conclusions The correlations between uncalibrated DSA measurements and CTA for vessel diameter were strong. In addition, there were strong correlations between these image types for repeated measurements in the image isocenter as well as image periphery for vessel diameter. Consequently, endovascular devices can be sized correctly without the need for pre-operative non-invasive imaging.

Funder

Crafoordska Stiftelsen

Skånes universitetssjukhus

Publisher

SAGE Publications

Subject

Immunology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3