Long-term results of wide-necked intracranial bifurcation aneurysms treated with stent-assisted coiling using low-profile acandis acclino stents

Author:

Melber Katharina1,Boxberg Frederik W1ORCID,Schlunz-Hendann Martin1,Brassel Friedhelm2,Grieb Dominik F J13ORCID

Affiliation:

1. Department of Radiology and Neuroradiology, Sana Kliniken Duisburg, Duisburg, Germany

2. Sana Kliniken Duisburg, Duisburg, Germany

3. Department of Diagnostic and Interventional Neuroradiology, Medical School Hannover, Hannover, Germany

Abstract

Purpose Little data exists on endovascular treatment of complex intracranial aneurysms with the Acandis Acclino low-profile self-expanding closed-cell stent systems and is mainly limited to short- or midterm results. We report our long-term, single-centre experience with three generations of Acclino stents treating complex intracranial aneurysms. Methods 62 wide-necked intracranial aneurysms were treated electively using 88 Acclino stent systems. Single stent-assisted coiling was the preferred treatment in 38 cases and the kissing-Y stenting technique in 24 cases. We analysed demographic data and long-term follow-up results. Results All stents were successfully deployed with immediate complete (Raymond Roy occlusion classification, RROC I) or near-complete occlusion (RROC II) achieved in 93,5%. Follow-up was available in 55 cases with a mean follow-up of 36 months (range 9–80 months). Long-term RROC I or II was achieved in 49 cases (89,1%). Three cases of stable residual aneurysmal filling were observed (5,5%). Seven aneurysms (12,7%) demonstrated a worsening on follow-up leading either to a neck remnant (4 cases, 7,3%) or to an aneurysm recurrence (3 cases, 5,5%). One recurrent aneurysm was retreated with coilembolization (1,8%). The directly procedural-related complication rate was 4,8%. Seven cases of clinically silent in-stent stenosis (12,7%; morbidity n = 0) were detected on long-term follow-up, six of them using the kissing-Y stenting technique. Conclusion Endovascular treatment of various intracranial aneurysms using the Acandis Acclino stent systems is safe and efficient with high aneurysm occlusion rates combined with low complication rates on long-term follow-up. Overall, rates of in-stent stenosis are low but may depend on the treatment technique (single stent-assisted coiling versus kissing-Y stenting with coiling).

Publisher

SAGE Publications

Subject

Immunology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3