Optical coherence tomography: Translation from 3D-printed vascular models of the anterior cerebral circulation to the first human images of implanted surface modified flow diverters

Author:

Martínez-Galdámez Mario1,Escartín Jorge1,Pabón Boris2,Diaz Carlos23,Martín-Reyes Roberto4,Hermosín Antonio1,Crespo Eduardo1,Rodríguez Claudio1,Monedero Gonzalo1,Joshi Krishna5,Lopes Demetrius K6

Affiliation:

1. Endovascular Neurosurgery/Interventional Neurosurgery, Interventional Institute, Fundación Jiménez-Diaz, Madrid, Spain

2. Angioteam-Angiosur, Medellín, Colombia

3. Department of Radiology, Universidad de Antioquía, Medellín, Colombia

4. Interventional Cardiology Department, Fundación Jiménez-Diaz, Madrid, Spain

5. Department of Neurological Surgery, Rush University Medical Center, Chicago, IL, USA

6. Advocate Health, Cerebrovascular Neurosurgery and Comprehensive Stroke Center, Chicago, IL, USA

Abstract

Background The new generation of flow diverters includes a surface modification with a synthetic biocompatible polymer, which makes the device more biocompatible and less thrombogenic. Optical coherence tomography (OCT) can be used to visualize perforators, stent wall apposition, and intra-stent thrombus. Unfortunately real world application of this technology has been limited because of the limited navigability of these devices in the intracranial vessels. In this report, we share our experience of using 3D-printed neurovascular anatomy models to simulate and test the navigability of a commercially available OCT system and to show the application of this device in a patient treated with the new generation of surface modified flow diverters. Material and methods Navigability of OCT catheters was tested in vitro using four different 3D-printed silicone replicas of the intracranial anterior circulation, after the implantation of surface modified devices. Intermediate catheters were used in different tortuous anatomies and positions. After this assessment, we describe the OCT image analysis of a Pipeline Shield for treating an unruptured posterior communicating artery (PCOM) aneurysm. Results Use of intermediate catheters in the 3D-printed replicas was associated with better navigation of the OCT catheters in favorable anatomies but did not help as much in unfavorable anatomies. OCT image analysis of a PCOM aneurysm treated with Pipeline Embolization Device Shield demonstrated areas of unsatisfactory apposition with no thrombus formation. Conclusions OCT improves the understanding of the flow diversion technology. The development of less thrombogenic devices, like the Pipeline Flex with Shield Technology, reinforces the need for intraluminal imaging for neurovascular application.

Publisher

SAGE Publications

Subject

Immunology

Cited by 18 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3