Safety and efficacy of braided stents as stent monotherapy for the treatment of small intracranial aneurysms

Author:

Capirossi Carolina12ORCID,Radu Razvan A13ORCID,Gascou Gregory1,Lefevre Pierre-Henri1,Dargazanli Cyril1,Machi Paolo4,Costalat Vincent1,Cagnazzo Federico1ORCID

Affiliation:

1. Neuroradiology Department, Hospital Gui de Chauliac, Montpellier, France

2. Interventional Neuroradiology Unit, University Hospital Careggi, Florence, Italy

3. Clinical Neurosciences, “Carol Davila” University of Medicine and Pharmacy Bucharest, Bucharest, Romania

4. Neuroradiology Department, University of Geneva, Geneve, Switzerland

Abstract

Background The safety and efficacy of low-profile braided stent as stent monotherapy require further investigation. Objective To analyze patient outcomes after treatment with braided stents used as “light” flow diverters. Material/Methods Retrospective study to evaluate the occlusion rate of aneurysms treated with braided stent and remodeling of covered side branches and perforators. Several factors potentially influencing aneurysm occlusion were analyzed. Results Thirty-five aneurysms in 31 patients were included. Six aneurysms (17.1%) had an acute subarachnoid hemorrhage. Braided stent was used as retreatment among 9 previously coiled aneurysms (25.7%). A total occlusion was achieved in 18 aneurysms (51.4%), entry remnant in 3 aneurysms (8.6%), incomplete filling in 6 aneurysms (17.1%) and complete filling in 8 aneurysms (22.9%). None of the aneurysms ruptured during the follow-up period. Of 32 stents deployed, we observed 3 cases (9.4%) of asymptomatic mild stenosis and 3 cases (10.7%) of narrowing of covered branches among 28 covered arteries. There were no cases of perforator infarction and no mortality or permanent morbidity associated with the treatment. Moreover, aneurysms <2.5 mm, aneurysms with a neck <1.8 mm, those with a mean aspect-ratio of 1.4, and lateral wall aneurysms had a higher frequency of adequate occlusion. Conclusion Braided stents used as stent monotherapy appear to be sufficiently effective in the treatment of very small intracranial aneurysms, despite a lower overall occlusion rate compared to a standard flow diversion strategy. However, given the low morbidity rate, this strategy may be an alternative to flow-diverter stents for small and distally located lesions.

Publisher

SAGE Publications

Subject

General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Metal allergy and neurovascular stenting: A systematic review;Interventional Neuroradiology;2024-01-15

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3