Quantitative evaluation of the effects of flow diverter treatment on aneurysm hemodynamics using time-resolved rotational angiography

Author:

Peterson Jeremy C1ORCID,DiNitto Julie M2ORCID,Birkhold Annette3,Kahn Nickalus1,Nickele Christopher1,Hoit Dan1,Inoa Violiza1ORCID,Elijovich Lucas1,Dornbos David1,Arthur Adam S1ORCID

Affiliation:

1. Semmes-Murphey Clinic, Memphis, TN, USA

2. Siemens Medical Solutions, Malvern, PA, USA

3. Employee of Siemens Healthcare GmbH, Forchheim, Germany

Abstract

Background There have been immense advancements in the hardware and software of digital subtraction angiography systems over the last several years. These advancements continue to make progress toward the goals of offering better visualization and reducing radiation exposure. A newer advancement in this arena is presenting three-dimension data over time resulting in four-dimensional-digital subtracted angiography visualization. We have evaluated these protocols related to the evaluation of the treatment of intracranial aneurysms with pipeline flow diversion. Methods Four-dimensional-digital subtracted angiography imaging was acquired on an Artis Q Biplane angiographic system (Siemens Healthcare AG, Forchheim, Germany). A six second four-dimensional-digital subtracted angiography protocol was performed pre and post flow diverter placement. Pre and post reconstructed images were sent through a dedicated prototype research workstation (Syngo X-Workplace; Siemens Healthineers AG) for further flow evaluation. Results The treatment of an aneurysm with flow diversion led to a filling delay of 0.278 ± 0.422 s inside the aneurysms, whereas distal to the aneurysms the filling of the vessel segment occurred earlier post procedural (negative filling delay of −0.15 ± 0.31 s. The flow ratio inside the aneurysm decreased to 63.6 ± 23% of its pre-treatment value and distal to the aneurysm the flow remained substantially the same (flow ratio: 95.6 ± 0.29%). Data showed a relative filling delay of the aneurysm normalized to the distal vessel of 0.43 ± 0.36 s. The relative flow ratio of the aneurysm in comparison to the distal parent vessel was 72.2 ± 31%. Conclusions Analysis of a four-dimensional-digital subtracted angiography acquisition allows assessment of the effects of flow diversion treatment on aneurysm hemodynamic parameters and shows a significant decrease in flow inside the aneurysm compared to the parent vessel distal to the aneurysm.

Funder

Siemens Medical Solutions USA

Publisher

SAGE Publications

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3