Focus on the target: Angiographic features of the fistulous point and prognosis of transvenous embolization of cavernous sinus dural arteriovenous fistula

Author:

Guo Hui12,Yin QianKun13,Liu Peng1ORCID,Guan Ning1,Huo Xiaochuan1,Li Youxiang1

Affiliation:

1. Department of Interventional Neuroradiology, Beijing Neurosurgical Institute and Beijing Tiantan Hospital, Capital Medical University, Beijing, China

2. Department of neurosurgery, aerospace center hospital, Haidian, Beijing, China

3. Department of Neurosurgery, Puyang People’s Hospital, Henan, China

Abstract

Background and purpose Transvenous embolization (TVE) is widely utilized as an effective and safe treatment option for cavernous sinus dural arteriovenous fistula (CS-dAVF); however, detecting the exact location of the fistula is challenging. The present study identified the angiographic features of the fistulous point and evaluated the match with the microcatheter tip and fistulous point. Materials and methods An analysis cohort of 45 consecutive patients with CS-dAVF treated by TVE was analyzed retrospectively. The patients were divided into two groups, 22 matches and 23 mismatches, according to whether the fistulous point and the microcatheter tip were in the same compartment of the cavernous sinus (CS). The angiographic findings, the location of the fistulas, the position of the microcatheter tips, the volume of embolic materials, complications, and outcomes were assessed. Results Several angiographic features defined the fistulous points, such as the early opacified area, jellyfish-like sign, changes in the density of the contrast medium, the juncture of different arterial supply, enlarged feeders, and hand-injection angiograms. The fistulas were primarily in the posterosuperior portion of the CS (80%) and medial side (73.3%) according to the internal carotid artery. Both groups achieved effective TVE; the matched group required less embolic material than the mismatched group ( p = 0.024). The patients with cranial nerve dysfunction (CND) required more embolic materials than others ( p = 0.032). Conclusion The fistulous point in most of the CS-dAVFs could be isolated by careful analysis of the angiography images. The matching of the microcatheter tip and fistulous point in the same compartment of CS can reduce the dosage of embolic materials, and a low volume of embolic materials might cause fewer CND complications.

Publisher

SAGE Publications

Subject

Immunology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3