Factors related to insufficient hemostasis using the EXOSEAL vascular closure device with five-minutes compression for femoral artery punctures after neuro-endovascular therapy: A retrospective, single-center experience

Author:

Izawa Daisuke1ORCID,Matsumoto Hiroyuki1ORCID,Nishiyama Hirokazu1,Nakayama Yukie1,Maeshima Kazuhide1

Affiliation:

1. Department of Neurological Surgery, Kishiwada Tokushukai Hospital, Osaka, Japan

Abstract

Objectives The aim was to identify the factors related to inadequate hemostasis with five minutes of manual compression using the EXOSEAL vascular closure device (VCD), and to evaluate the optimal time to hemostasis (TTH). Methods A total of 119 consecutive patients who underwent neuro-endovascular therapy via common femoral arterial puncture between February 2019 and August 2021 were included. These patients underwent hemostasis using an EXOSEAL with manual compression for five minutes. In this retrospective study, the 119 patients were divided into two groups: (1) achieved hemostasis with five minutes (n = 76); and (2) required more than five minutes to achieve hemostasis (n = 43, Add group). In both groups, patient's characteristics, endovascular procedures, and closure procedures were assessed. Results On univariable analysis, activated clotting time (ACT), multiple antiplatelets, closure with an under-sized EXOSEAL VCD (U-VCD), endovascular procedure, and use of a 7Fr. VCD were significantly associated with additional compression ( p < 0.05). On multivariate logistic regression analysis, the following three factors were found to be associated with additional compression: pre-closure ACT (adjusted OR, 0.136; 95% CI, 1.017–1.056; p < 0.001); multiple antithrombotics (adjusted OR, 12.843; 95% CI, 3.458–47.693; p < 0.001); and closure with a U-VCD (adjusted OR, 5.653; 95% CI, 1.751–18.151; p = 0.004). On the receiver-operating characteristic curve analysis for prediction of the need for additional compression, the cutoff point for pre-closure ACT was calculated to be 268 s. In the Add group, mean TTH was 9.8 ± 1.5 min. Conclusion Multiple antiplatelets and closure with a U-VCD may increase the risk of insufficient hemostasis with five-minutes compression using an EXOSEAL VCD for femoral puncture sites if the pre-closure ACT is greater than 268 s. In these patients, mean TTH was 9.8 ± 1.5 min.

Publisher

SAGE Publications

Subject

Immunology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3