A comparison of endovascular coil systems for the treatment of small intracranial aneurysms

Author:

Begley Sabrina L1ORCID,White Timothy G1ORCID,Shah Kevin A1ORCID,Turpin Justin1ORCID,Toscano Daniel1,Dehdashti Amir R1,Teron Ina1,Link Thomas1,Patsalides Athos2,Woo Henry H1

Affiliation:

1. Department of Neurosurgery, Donald and Barbara Zucker School of Medicine at Hofstra/Northwell, Manhasset, NY, USA

2. Department of Neurology, Donald and Barbara Zucker School of Medicine at Hofstra/Northwell, Manhasset, NY, USA

Abstract

Background Endovascular coiling of small, intracranial aneurysms remains controversial and difficult, despite advances in technology. Methods We retrospectively reviewed data for 62 small aneurysms (<3.99 mm) in 59 patients. Occlusion rates, complications rates, and coil packing densities were compared between subgroups based upon coil type and rupture status. Results Ruptured aneurysms predominated (67.7%). Aneurysms measured 2.99 ± 0.63 mm by 2.51 ± 0.61 mm with an aspect ratio of 1.21 ± 0.34 mm. Brands included Optima (Balt) (29%), MicroVention Hydrogel (24.2%), and Penumbra SMART (19.4%) coil systems. Average packing density was 34.3 ± 13.5 mm3. Occlusion rate was 100% in unruptured aneurysms; 84% utilized adjuvant devices. For ruptured aneurysms, complete occlusion or stable neck remnant was achieved in 88.6% while recanalization occurred in 11.4%. No rebleeding occurred. Average packing density ( p = 0.919) and coil type ( p = 0.056) did not impact occlusion. Aspect ratio was smaller in aneurysms with technical complications ( p = 0.281), and aneurysm volume was significantly smaller in those with coil protrusion ( p = 0.018). Complication rates did not differ between ruptured and unruptured aneurysms (22.6 vs. 15.8%, p = 0.308) or coil types ( p = 0.830). Conclusion Despite advances in embolization devices, coiling of small intracranial aneurysms is still scrutinized. High occlusion rates are achievable, especially in unruptured aneurysms, with coil type and packing density suggesting association with complete occlusion. Technical complications may be influenced by aneurysm geometry. Advances in endovascular technologies have revolutionized small aneurysm treatment, with this series demonstrating excellent aneurysm occlusion especially in unruptured aneurysms.

Publisher

SAGE Publications

Subject

Immunology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3