Proximal balloon-guided catheter with flow inversion vs. distal filter protection during the carotid stent placement, a seven years experience in a Colombian reference center

Author:

Garcia-Ledesma O12ORCID,Mantilla D13ORCID,Correa-Ruiz PA4,D Vera D4ORCID,Valenzuela-Santos C5ORCID,Serrano-Gómez S6ORCID,Reyes A6ORCID,Galvis M13,Ferreira-Prada CA13ORCID,Vargas O13

Affiliation:

1. Interventional radiology Department. Fundación oftalmológica de Santander - Clínica Ardila Lülle. Floridablanca, Colombia

2. Radiology Department. Fundación Valle del Lili. Cali, Colombia

3. Interventional radiology Department. Universidad Autónoma de Bucaramanga. Bucaramanga, Colombia

4. Universidad Autónoma de Bucaramanga. Bucaramanga, Colombia

5. Radiology Department. Fundación oftalmológica de Santander - Clínica Ardila Lülle. Floridablanca, Colombia

6. Clinical Research Group-UNAB, Universidad Autónoma de Bucaramanga, Bucaramanga, Colombia

Abstract

Background and purpose The carotid stent placement as a therapeutic option for carotid stenosis has been increasing among years; therefore, studies are required to evaluate the security and efficacy of its materials. The purpose of this study was to evaluate the distal filter and the proximal balloon-guided catheter with flow inversion as protection devices during carotid angioplasty and stenting. Methods This is a retrospective, observational study of patients diagnosed with carotid stenosis treated with angioplasty between January 1, 2014, and June 30, 2020; we analyzed a radiology service database to compare the distal filter and the proximal balloon-guided catheter as protection devices during angioplasty. Results One hundred seventy-five angioplasties were performed, the distal filter was the most prevalent embolic protection device used (66%), patients baseline characteristics did not differ between groups with different embolic protection devices, except for history of dyslipidemia ( p  <  0.000). As well, we did not find any significant differences between the groups in the device related complications, intervention time ( p  =  0.140), unrelated complications ( p  =  0.693) and functional independence at 90 days (p =  0.096). Conclusions In our study the proximal balloon-guided catheter and the distal filter protection device as protection devices during the carotid stenting didn't show significant differences regarding complications related to the system.

Publisher

SAGE Publications

Subject

Immunology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Elective carotid stenting fulfills quality standards defined in guidelines;RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren;2023-11-14

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3