Safety of stent-assisted coiling for the treatment of wide-necked ruptured aneurysm: A systematic literature review and meta-analysis of prevalence

Author:

Bsat Shadi1,Bsat Ayman2ORCID,Tamim Hani3,Chanbour Hani2,Alomari Safwan Omar1,Houshiemy Mohamad Nabih El1,Moussalem Charbel1,Omeis Ibrahim14

Affiliation:

1. Department of Neurosurgery, American University of Beirut Medical Center, Beirut, Lebanon

2. Faculty of Medicine, Lebanese University, Beirut, Lebanon

3. Department of Internal Medicine, American University of Beirut Medical Center, Beirut, Lebanon

4. Department of Neurosurgery, Baylor College of Medicine, Houston, TX, USA

Abstract

Background Stent-assisted coil embolization of ruptured wide-necked aneurysms is a controversial treatment modality due to concerns on the peri-procedural safety of anti-platelet therapy in the setting of acute subarachnoid hemorrhage. Our aim was to systematically review the literature on stent-assisted coil embolization of acutely ruptured wide-neck aneurysms to calculate the pooled prevalence of clinical outcome, thromboembolic and hemorrhagic complication rates and overall mortality. Methods We searched PubMed and Google Scholar for articles published between 2009 and 2019 and stratified selected articles based on risk of publication bias. Data on thromboembolic and hemorrhagic complications, clinical outcomes and mortality rates were analyzed using quality-effects model and double arcsine transformation. Results 24 articles were included featuring a total of 1582 patients. Thromboembolic and hemorrhagic complication rates were witnessed in 9.1% [95% CI: 6.0% – 12.7%; I2 = 72.8%] and 8.7% [95% CI: 5.4 – 12.6%; I2 = 77.2%] of patients, respectively. 245 patients received external ventricular drains, of which 33 (13.5%) had EVD-related hemorrhages. Total complication rate was 20.8% [95% CI: 14.2 – 28.1%; I2 = 87.0%]. 57% of aneurysms were completely occluded and a favorable clinical outcome was reported in 74.7% [95% CI: 66.4 – 82.2%; I2 = 86.0] of patients. Overall mortality rate came at 7.8% [95% CI: 4.8 – 11.6%; I2 = 76.9%]. Conclusion Stent-assisted coiling of ruptured intracranial aneurysm is a technically feasible procedure with controlled thromboembolic complication rate but may be associated with higher hemorrhagic and total complication rates compared to coiling alone. While stent-assisted coiling of ruptured wide-necked aneurysm seems to yield a lower rate of favorable clinical outcome, overall mortality is comparable to that of endovascular coiling alone.

Publisher

SAGE Publications

Subject

Immunology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3