UTE T2* mapping of tendinopathic patellar tendons: an MRI reproducibility study

Author:

Agergaard Anne-Sofie123,Malmgaard-Clausen Nikolaj M12ORCID,Svensson Rene B12,Nybing Janus D4,Boesen Mikael45,Kjaer Michael12,Magnusson S. Peter12,Hansen Philip4

Affiliation:

1. Institute of Sports Medicine Copenhagen, Department of Orthopedic Surgery, Bispebjerg and Frederiksberg Hospital, Copenhagen, Denmark

2. Center for Healthy Aging, Faculty of Health Sciences, University of Copenhagen, Copenhagen, Denmark

3. Department of Physical and Occupational Therapy, Bispebjerg and Frederiksberg Hospital, Copenhagen, Denmark

4. Department of Radiology, Copenhagen University Hospital, Bispebjerg and Frederiksberg, Copenhagen, Denmark

5. Parker Institute, Bispebjerg and Frederiksberg Hospital, Copenhagen, Denmark

Abstract

Background There is currently a lack of imaging modalities that can be used as a sensitive measure in tendinopathy. Recent findings suggest the applicability of ultra-short echo time (UTE) magnetic resonance imaging (MRI) T2* mapping in tendons, but the reproducibility remains unknown. Purpose To evaluate test–retest reproducibility of UTE MRI T2* mapping of tendinopathic patellar tendons and to evaluate the intra- and inter-observer reproducibility of the measurement. Material and Methods Fifteen patients with chronic patellar tendinopathy were evaluated with UTE MRI twice in a 3.0-T scanner on the same day. Manual segmentation of the patellar tendon was performed by two blinded investigators and automated T2*map reconstruction was performed in custom-made software. Results There was a significant and numerically small difference in test–retest T2* values (T2*meandiff = 0.06 ± 0.07 ms ≈ 3.7%; P = 0.006) with an ICC = 0.91 (95% confidence interval [CI] 0.58–0.98; typical error of 3.0%). The intra- and inter-observer reproducibility showed no significant bias ( P = 0.493 and P = 0.052), and generally substantial reproducibility was demonstrated for T2* (intra-observer ICC = 0.99; 95% CI 0.98–1.00 and inter-observer ICC = 0.99; 95% CI 0.96–1.00, and typical error 1.3% and 1.3%, respectively). Conclusion These data demonstrate a small bias between repeated measurements for UTE T2*, but with a very low associated mean difference (3.7%) between the two tests. The high ICC values and low typical error % demonstrate reproducibility of repeated T2*-mapping sessions. Further, the method showed substantial intra- and inter-observer reproducibility for T2* values proving feasibility for use of UTE T2* mapping in research and clinical practice.

Publisher

SAGE Publications

Subject

Radiology, Nuclear Medicine and imaging,General Medicine,Radiological and Ultrasound Technology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3