The impact of iodine contrast agent on radiation dose of heart and blood: a comparison between coronary CT angiography and cardiac calcium scoring CT

Author:

Mazloumi Mahta1ORCID,Van Gompel Gert1,Tanaka Kaoru1,Argacha Jean-François2,de Mey Johan1,Buls Nico1

Affiliation:

1. Department of Radiology, Vrije Universiteit Brussel, Universitair Ziekenhuis Brussel (UZ Brussel), Brussels, Belgium

2. Department of Cardiology, Vrije Universiteit Brussel, Universitair Ziekenhuis Brussel (UZ Brussel), Brussels, Belgium

Abstract

Background Iodine contrast agent (CA) is widely used in cardiac computed tomography (CT). The CA can increase the organ radiation doses due to the photoelectric effect. Purpose To investigate the impact of CA on radiation dose in cardiac CT by comparing the radiation dose between contrast coronary CT angiography (CCTA) and non-contrast calcium scoring CT (CSCT). Material and Methods Radiation doses were computationally calculated for 30 individual patients who received CSCT and CCTA in the same exam session. The geometry and acquisition parameters were modeled in the simulations based on individual patient CT images and acquisitions. Doses in the presence and absence of CA were obtained in the aorta, left ventricle (LV), right ventricle (RV), and myocardial tissue (MT). The dose values were normalized by size-specific dose estimate (SSDE). The dose enhancement factors (DEFSSDE) were calculated as the ratio of doses in CCTA over doses in CSCT. Results Compared to the CSCT scans, doses increase in the CCTA scans in the aorta (DEFSSDE = 2.14 ± 0.20), LV (DEFSSDE = 1.78 ± 0.26), and RV (DEFSSDE = 1.31 ± 0.22). A linear relation is observed between the local CA concentrations and the dose increase in the heart; DEFSSDE = 0.07*I(mg/mL) + 0.80 (R2 = 0.8; p < 0.01). The DEFSSDE in the MT (DEFSSDE = 0.96 ± 0.08) showed no noticeable impact of CA on the dose in this tissue. In addition, patient variability in the dose distributions was observed. Conclusion A linear causal relation exists between local CA concentration and increase in radiation dose in cardiac CT. For the same CT exposure, dose to the heart is on average 55% higher in contrast cardiac CT.

Funder

Fonds Wetenschappelijk Onderzoek

Publisher

SAGE Publications

Subject

Radiology, Nuclear Medicine and imaging,General Medicine,Radiological and Ultrasound Technology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3