Using modulated and smoothed data improves detectability of volume difference in group comparison, but reduces accuracy with atlas-based volumetry using Statistical Parametric Mapping 12 software

Author:

Goto Masami1ORCID,Murata Syo2,Hori Masaaki2,Nemoto Kiyotaka3,Kamatgata Koji2,Aoki Shigeki2,Abe Osamu4,Sakamoto Hajime1,Sakano Yasuaki1,Kyogoku Shinsuke1,Daida Hiroyuki1

Affiliation:

1. Department of Radiological Technology, Faculty of Health Science, Juntendo University, Juntendo University, Tokyo, Japan

2. Department of Radiology, Juntendo University School of Medicine, Tokyo, Japan

3. Department of Neuropsychiatry, Division of Clinical Medicine, Faculty of Medicine, University of Tsukuba, Ibaraki, Japan

4. Department of Radiology, The University of Tokyo Hospital, Tokyo, Japan

Abstract

Background Atlas-based volumetry using three-dimensional T1-weighted (3D-T1W) magnetic resonance imaging (MRI) has been used previously to evaluate the volumes of intracranial tissues. Purpose To evaluate the detectability of volume difference and accuracy for volumetry using smoothed data with an atlas-based method. Material and Methods Twenty healthy individuals and 24 patients with idiopathic normal-pressure hydrocephalus (iNPH) underwent 3-T MRI, and sagittal 3D-T1W images were obtained in all participants. Signal values (as tissue probability) of voxels in five segmented data types (gray matter, white matter, cerebrospinal fluid [CSF], skull, soft tissue) derived from the 3D-T1W images with SPM 12 software were assigned simulated 3D-T1W signal intensities to each tissue image. The assigned data were termed “reference data.” We created a reference 3 D-T1W image that included the reference data of all five tissue types. Standard volumes were measured for the reference CSF data with region of interest of lateral ventricle in native space, and measured volumes were obtained for non-smoothed and smoothed-modulated data. Detectability was evaluated between measured volumes in the healthy control and iNPH groups. Accuracy was evaluated as the difference between the mean measured and standard volumes. Results In group comparison of measured volumes between the healthy control and iNPH groups, the lowest P value was for smoothed-modulated CSF data. In both groups, the largest difference from the standard volume was found for the mean of the measured volumes for smoothed-modulated CSF data. Conclusion Our study shows that using smoothed data can improve detectability in group comparison. However, using smoothed data reduces the accuracy of volumetry.

Publisher

SAGE Publications

Subject

Radiology Nuclear Medicine and imaging,General Medicine,Radiological and Ultrasound Technology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3