Intra-individual comparison of lumbar spine CT, abdomen-pelvis contrast enhanced CT, and low-dose chest CT for bone density measurement

Author:

Park Jina1ORCID,Kim Bo Ram1ORCID,Lee Eugene1ORCID,Lee Joon Woo12ORCID

Affiliation:

1. Department of Radiology, Seoul National University Bundang Hospital, Seongnam, Gyeonggi-do, Republic of Korea

2. Department of Radiology, Seoul National University College of Medicine, Seoul, Republic of Korea

Abstract

Background Dual-energy X-ray absorptiometry (DXA) is the reference standard for the measurement of bone mineral density (BMD) and subsequent diagnosis of osteoporosis. Since various computed tomography (CT) protocols are scanned for various indications, we can incidentally measure BMD using CT. Previous studies have revealed a correlation between BMD and Hounsfield unit (HU) values obtained with different CT protocols. Purpose To compare the diagnostic value of CT protocols (lumbar spine CT [LSCT], abdomen-pelvis contrast-enhanced CT [APCT], and low-dose chest CT [LDCT]) for osteoporosis. Material and Methods We retrospectively included 17 patients (6 men, 11 women; mean age=68 years) who had undergone all four imaging studies within six months, during 2011–2021. HU values were manually measured at the center of the L1 vertebra by a radiology resident. Pearson correlation test was performed between HU values and BMD of L1 vertebra. The diagnostic performance of each CT protocol was assessed with receiver operating characteristic (ROC) analysis. Intra-individual concordance of the four tests to diagnose osteoporosis was analyzed by tabulating. Results The mean HU values were 104.4 ± 47.2 HU with LSCT, 149.0 ± 56.9 HU with APCT, and 114.3 ± 60.0 HU with LDCT. HU values from each protocol were positively correlated (r = 0.676-0.735; P < 0.005) with BMD. LDCT had the highest diagnostic performance (area under the ROC curve [AUC] = 0.701) and APCT the lowest (AUC = 0.569). APCT was discordant with the other protocols for diagnosing osteoporosis. Conclusion LDCT had the highest diagnostic performance for osteoporosis with predetermined cutoff value. APCT requires the increase of cutoff value for osteoporosis diagnosis.

Publisher

SAGE Publications

Subject

Radiology, Nuclear Medicine and imaging,General Medicine,Radiological and Ultrasound Technology

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3