Does mammographic density remain a radiological challenge in the digital era?

Author:

Al-Mousa Dana S1ORCID,Rawashdeh Mohammad1,Alakhras Maram1,Spuur Kelly M2,AbuTaimai Rula3,Brennan Patrick C4

Affiliation:

1. Department of Allied Medical Sciences, Faculty of Applied Medical Sciences, Jordan University of Science and Technology, Irbid, Jordan

2. School of Dentistry and Health Sciences, Charles Sturt University, Wagga Wagga, NSW, Australia

3. Jordan Breast Cancer Program (JBCP), Amman, Jordan

4. Medical Image Optimisation and Perception Group (MIOPeG), Discipline of Medical Imaging and Radiation Sciences, Faculty of Health Sciences, The University of Sydney, Sydney, NSW, Australia

Abstract

Background The low subject contrast between cancerous and fibroglandular tissue could obscure breast abnormalities. Purpose To investigate radiologists’ performance for detection of breast cancer in low and high mammographic density (MD) when cases are digitally acquired. Material and Methods A test set of 60 digital mammography cases, of which 20 were cancerous, were examined by 17 radiologists. Mammograms were categorized as low (≤50%) or high (>50%) MD and rated for suspicion of malignancy using the Royal Australian and New Zealand College of Radiology (RANZCR) classification system. Radiologist demographics including cases read per year, age, subspecialty, and years of reporting were recorded. Radiologist performance was analyzed by the following metrics: sensitivity; specificity; area under the receiver operating characteristic (ROC) curve (AUC), location sensitivity, and jackknife free-response ROC (JAFROC) figure of merit (FOM). Results Comparing high to low MD cases, radiologists showed a significantly higher sensitivity ( P = 0.015), AUC ( P = 0.003), location sensitivity ( P = 0.002), and JAFROC FOM ( P = 0.001). In high compared to low MD cases, radiologists with <1000 annual reads and radiologists with no mammographic subspecialty had significantly higher AUC, location sensitivity, and JAFROC FOM. Radiologists with ≥1000 annual reads and radiologists with mammography subspecialty demonstrated a significant increase in location sensitivity in high compared to low MD cases. Conclusion In this experimental situation, radiologists’ performance was higher when reading cases with high compared to low MD. Experienced radiologists were able to precisely localize lesions in breasts with higher MD. Further studies in unselected screening materials are needed to verify the results.

Funder

Jordan University of Science and Technology

Publisher

SAGE Publications

Subject

Radiology, Nuclear Medicine and imaging,General Medicine,Radiological and Ultrasound Technology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3