Fluoroscopically guided repositioning of peripherally inserted central catheter in patients failing ultrasound-guided-only placement: a retrospective five-year study

Author:

Wang Zi-Xuan1ORCID,Li Lin1,Zhao Yi-Fan1

Affiliation:

1. Department of Interventional Radiology, Qingdao Hospital, University of Health and Rehabilitation Sciences (Qingdao Municipal Hospital), Qingdao, PR China

Abstract

Background Ultrasound (US)-guided-only insertion at the bedside is safe and improves the success rates of peripherally inserted central catheter (PICC). However, PICC insertion procedures remain challenging for special cases. Purpose To show that fluoroscopically guided tip repositioning, for failed US-guided PICC placement, safely led to satisfactory positioning in difficult cases and, importantly, improved success rates of PICC placements. Material and Methods A retrospective study of 1560 patients who underwent US-guided PICC placement were performed. Patients who failed US-guided PICC placement were transferred to the interventional radiology department for fluoroscopically guided tip repositioning. Baseline characteristics as well as insertion-related factors were collected. All data were analyzed using SPSS software. Results In total, 37 (2.4%) patients who failed US-guided PICC placement accepted fluoroscopically guided adjustment or re-insertion. Of these 37 patients, 32 were enrolled. We observed no significant differences between right and left arm PICC access ( P > 0.05), even though a higher percentage of PICCs were inserted into left arms (56.3%). The basilic vein (65.6%) was the most common insertion site. Only four patients experienced slight angiospasm (3.1%) and venous thrombosis (9.4%). US-guided PICC insertion failures were primarily due to line tip malposition (84.4%). All patients successfully underwent fluoroscopically guided tip repositioning, which resulted in optimal catheter tip positioning. PICC lines were adjusted in most patients (n=28, 87.5%) Conclusion Malposition was the primary issue causing US-guided PICC insertion failure. Fluoroscopically guided tip repositioning safely and efficaciously led to satisfactory positioning in difficult cases; thus, we recommend this method for patients failing US-guided PICC placement.

Publisher

SAGE Publications

Subject

Radiology, Nuclear Medicine and imaging,General Medicine,Radiological and Ultrasound Technology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3