Triple rule-out CT angiography protocol with restricting field of view for detection of pulmonary thromboembolism and aortic dissection in emergency department patients: simulation of modified CT protocol for reducing radiation dose

Author:

Kim Hyun Su1,Kim Sung Mok12,Cha Min Jae1,Kim Yoo Na1,Kim Hae Jin1,Choi Jin-Ho23,Choe Yeon Hyeon12

Affiliation:

1. Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea

2. Cardiovascular Imaging Center, Heart Vascular and Stroke Institute, Samsung Medical Center, Seoul, Republic of Korea

3. Division of Cardiology, Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea

Abstract

Background Triple rule-out computed tomography (TRO CT) is a CT protocol designed to simultaneously evaluate the coronary, aorta, and pulmonary arteries. Purpose To evaluate potential diagnostic performance of TRO CT with restricted volume coverage for detection of pulmonary thromboembolism (PTE) and aortic dissection (AD). Material and Methods This study included 1224 consecutive patients with acute chest pain who visited the emergency department and underwent TRO CT using a 128-slice dual-source CT. Image data were reconstructed according to the display field of view (DFOV) of coronary CT angiography (CCTA) and TRO CT protocols in each patient. The presence of PTE and AD was evaluated by independent observers in each DFOV. The radiation dose was calculated to evaluate the potential benefits by restricting z-axis coverage to cardiac scan range instead of the whole thorax. Results Among all patients, 22 cases with PTE (1.9%) and nine cases with AD (0.8%) were found. Except for one PTE case, all cases were detected on both DFOV of TRO CT and CCTA. Mean effective dose for evaluation of entire thorax and cardiac scan coverage were 5.9 ± 1.1 mSv and 3.5 ± 0.7 mSv, respectively. Conclusion Isolated PTE and AD outside the CCTA DFOV rarely occur. Therefore, modified TRO CT protocol using cardiac scan coverage can be adopted to detect PTE and AD with reduced radiation dose.

Publisher

SAGE Publications

Subject

Radiology, Nuclear Medicine and imaging,General Medicine,Radiological and Ultrasound Technology

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3