Effects of gadolinium-based contrast agent concentrations (0.5 M or 1.0 M) on the diagnostic performance of magnetic resonance imaging examinations: systematic review of the literature

Author:

Lancelot Eric1,Froehlich John2,Heine Oliver3,Desché Pierre1

Affiliation:

1. GUERBET, Villepinte, France

2. GUERBET AG, Zürich, Switzerland

3. GUERBET GmbH, Sulzbach/Taunus, Germany

Abstract

Background To date there is no agreement as to what is the optimal concentration for gadolinium-based contrast agents (GBCAs). Purpose To assess whether diagnostic performance differences exist between 0.5 M and 1.0 M GBCAs used for magnetic resonance imaging (MRI). Material and Methods A PubMed literature search identified 21 clinical studies published between 2005 and 2013 which evaluated the diagnostic efficacy of both types of GBCAs. Study design, type of procedure, GBCA administration mode, imaging performances, impact on patient management, study limitations, and biases were analyzed. No statistical test was performed on pooled data. Results Sixteen comparative and five non-comparative studies were analyzed, involving 2183 patients who underwent MRI procedures for various indications. In 67% of the studies, 0.5 M and 1.0 M GBCAs were injected at equimolar gadolinium amounts per kg body weight. Only 33% applied the same molar flow rate for delivery of the GBCAs. No significant differences between GBCAs were reported for 23 out of 27 qualitative endpoints (mainly image quality, lesion, and vessel visualization) and 29 out of 40 quantitative endpoints. Three out of four studies with non-equimolar delivery rates showed better contrast-to-noise and signal-to-noise ratios for 1.0 M gadobutrol, without showing an impact on diagnostic performance. Methodological biases were identified in several studies impairing the interpretation of comparisons. Conclusion Imaging differences between 0.5 M and 1.0 M GBCAs were essentially observed under non-equimolar delivery rates. However, they did not result into greater diagnostic efficacy when performed under equimolar conditions.

Publisher

SAGE Publications

Subject

Radiology Nuclear Medicine and imaging,General Medicine,Radiological and Ultrasound Technology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3