Microwave ablation of 105 T1 renal tumors: technique efficacy with a mean follow-up of two years

Author:

Acosta Ruiz Vanessa1ORCID,Dahlman Pär1,Brekkan Einar2,Lönnemark Maria1,Magnusson Anders1

Affiliation:

1. Department of Surgical Sciences – Radiology, Uppsala University, Uppsala Sweden

2. Department of Surgical Sciences – Urology, Uppsala University, Uppsala Sweden

Abstract

Background Thermal ablation (TA) with radiofrequency (RFA) or cryoablation (CA) are established treatments for small renal masses (≤4 cm). Microwave ablation (MWA) has several potential benefits (decreased ablation time, less susceptibility to heat-sink, higher lesion temperatures than RFA) but is still considered experimental considering the available small-sample studies with short follow-up. Purpose To evaluate technique efficacy and complications of our initial experience of renal tumors treated using percutaneous MWA with a curative intent. Material and Methods A total of 105 renal tumors (in 93 patients) were treated between April 2014 and August 2017. MWA was performed percutaneously with computed tomography (CT) guidance under conscious sedation (n=82) or full anesthesia. Patients were followed with contrast-enhanced CT scans at six months and yearly thereafter for a minimum of five years. The mean follow-up time was 2.1 years. The percentage of tumors completely ablated in a single session (primary efficacy rate) and those successfully treated after repeat ablation (secondary efficacy rate) were recorded. Patient and tumor characteristics as well as complications were collected retrospectively. Results The median patient age was 70 years and median tumor size was 25 mm. Primary efficacy rate was 96.2% (101/105 tumors). After including two residual tumors for a second ablation session, secondary efficacy was 97.1% (102/105). Periprocedural complications were found in 5.2% (5/95) sessions: four Clavien-Dindo I and one Clavien-Dindo IIIa. One postprocedural Clavien-Dindo II complication was found. Conclusion MWA has high efficacy rates and few complications compared to other TA methods at a mean follow-up of two years.

Funder

The Japanese-Swedish Research Foundation

Publisher

SAGE Publications

Subject

Radiology Nuclear Medicine and imaging,General Medicine,Radiological and Ultrasound Technology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3