Comparison of submillisievert CT with standard-dose CT for urolithiasis

Author:

Shim Young Sup1,Park So Hyun1ORCID,Choi Seung Joon1,Ahn Su Joa1,Pak Seong Yong2,Jung Han3,Park Seong Ho4

Affiliation:

1. Department of Radiology, Gil Medical Center, Gachon University College of Medicine, Incheon, Republic of Korea

2. Healthcare Diagnostic Imaging Division, Siemens-healthineers, Seoul, Republic of Korea

3. Department of Urology, Gil Medical Center, Gachon University College of Medicine, Incheon, Republic of Korea

4. Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul, Republic of Korea

Abstract

Background Patients with renal stones receive multiple computed tomography (CT) examinations. We investigated whether submillisievert (sub-mSv) CT for stone detection could reduce radiation dose at exposure levels comparable to kidney, ureter, and bladder (KUB) radiography. Purpose To evaluate the radiation dose exposure, diagnostic performance, and image quality of sub-mSv non-contrast CT using advanced modelled iterative reconstruction algorithm with spectral filtration for the detection of urolithiasis. Material and Methods A total of 145 consecutive patients underwent non-contrast CT using a third-generation dual-source scanner to obtain two datasets, i.e. 16.7% (sub-mSv CT, tube detector A) and 100% (standard-dose CT, combination of tube detector A and B) tube loads with spectral filtration. The performance of sub-mSv CT for the detection of stones was analyzed by two readers and compared with that of standard-dose CT. Image quality was measured subjectively and objectively. Results In total, 171 stones were detected in 79 patients. The mean effective radiation doses of sub-mSv CT was 0.3 mSv. The sensitivity and specificity values for diagnosis of stones measuring ≥3 mm was 95.1% and 100% for sub-mSv CT. The sensitivity and specificity for all stone detection was 74.9% and 97.8%, respectivey, for sub-mSv CT. The image quality was lower for sub-mSv CT than for standard-dose CT ( P < 0.01). Conclusion Sub-mSv CT can be achieved with radiation doses close to KUB radiography. Sub-mSv CT with spectral filtration can be used to detect stones measuring ≥3 mm and be used as a follow-up imaging modality as an alternative to KUB radiography.

Funder

National Research Foundation of Korea

Publisher

SAGE Publications

Subject

Radiology, Nuclear Medicine and imaging,General Medicine,Radiological and Ultrasound Technology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3