Radiation exposure and establishment of diagnostic reference levels of whole-body low-dose CT for the assessment of multiple myeloma with second- and third-generation dual-source CT

Author:

Zensen Sebastian1ORCID,Bos Denise1ORCID,Opitz Marcel1ORCID,Haubold Johannes1ORCID,Forsting Michael1,Guberina Nika2,Wetter Axel1

Affiliation:

1. Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen, Germany

2. Department of Radiotherapy, University Hospital Essen, Essen, Germany

Abstract

Background In the assessment of diseases causing skeletal lesions such as multiple myeloma (MM), whole-body low-dose computed tomography (WBLDCT) is a sensitive diagnostic imaging modality, which has the potential to replace the conventional radiographic survey. Purpose To optimize radiation protection and examine radiation exposure, and effective and organ doses of WBLDCT using different modern dual-source CT (DSCT) devices, and to establish local diagnostic reference levels (DRL). Material and Methods In this retrospective study, 281 WBLDCT scans of 232 patients performed between January 2017 and April 2020 either on a second- (A) or third-generation (B) DSCT device could be included. Radiation exposure indices and organ and effective doses were calculated using a commercially available automated dose-tracking software based on Monte-Carlo simulation techniques. Results The radiation exposure indices and effective doses were distributed as follows (median, interquartile range): (A) second-generation DSCT: volume-weighted CT dose index (CTDIvol) 1.78 mGy (1.47–2.17 mGy); dose length product (DLP) 282.8 mGy·cm (224.6–319.4 mGy·cm), effective dose (ED) 1.87 mSv (1.61–2.17 mSv) and (B) third-generation DSCT: CTDIvol 0.56 mGy (0.47–0.67 mGy), DLP 92.0 mGy·cm (73.7–107.6 mGy·cm), ED 0.61 mSv (0.52–0.69 mSv). Radiation exposure indices and effective and organ doses were significantly lower with third-generation DSCT ( P < 0.001). Local DRLs could be set for CTDIvol at 0.75 mGy and DLP at 120 mGy·cm. Conclusion Third-generation DSCT requires significantly lower radiation dose for WBLDCT than second-generation DSCT and has an effective dose below reported doses for radiographic skeletal surveys. To ensure radiation protection, DRLs regarding WBLDCT are required, where our locally determined values may help as benchmarks.

Publisher

SAGE Publications

Subject

Radiology, Nuclear Medicine and imaging,General Medicine,Radiological and Ultrasound Technology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3