BLADE turbo gradient- and spin-echo in the assessment of sinonasal lesions: a comprehensive comparison of image quality in readout-segmented echo-planar imaging

Author:

Geng Yue1,Shi Yiqian1,Chen Wei1,Tang Zuohua1,Zhang Zhongshuai2,Zhou Kun3,Sha Yan1ORCID

Affiliation:

1. Department of Radiology, Eye & ENT Hospital, Fudan University, Shanghai Medical College, Shanghai, PR China

2. Scientific Marketing, Siemens Healthcare, Shanghai, PR China

3. Department of Digitalization, Siemens Shenzhen Magnetic Resonance Ltd., Shenzhen, PR China

Abstract

Background A two-dimensional turbo gradient-echo and spin-echo diffusion-weighted pulse sequence with a non-Cartesian BLADE trajectory (TGSE BLADE) can eliminate image artifacts and distortion with clinically acceptable scan times. This process has the potential to overcome the shortcomings of current diffusion-weighted imaging (DWI) techniques, especially in the sinonasal region. Purpose To investigate the feasibility of TGSE BLADE in the assessment of sinonasal lesions and compare the quality of TGSE BLADE with RESOLVE images both qualitatively and quantitatively. Material and Methods A total of 36 patients with sinonasal lesions were included in this prospective study. DW images acquired using TGSE BLADE and RESOLVE were performed with the same acquisition time. Two independent observers evaluated the qualitative parameters (overall image quality, lesion visibility, and geometric distortion) and quantitative parameters (geometric distortion ratio [GDR], signal-to-noise ratio [SNR], contrast, contrast-to-noise ratio [CNR], and apparent diffusion coefficient [ADC] value) of the two sequences. Results Qualitative assessment revealed that TGSE BLADE exhibited higher overall image quality ( P < 0.001) and lesion visibility ( P < 0.001) and less geometric distortion ( P < 0.001) than RESOLVE. Quantitative assessment showed that TGSE BLADE images exhibited higher contrast ( P < 0.001) and CNR ( P < 0.001) and lower GDR ( P < 0.05) and SNR ( P < 0.001) than RESOLVE images. The ADC value of TGSE BLADE was significantly lower than that of RESOLVE ( P < 0.05). Conclusion TGSE BLADE can reduce susceptibility artifacts and geometric distortion more than RESOLVE and appears to be a promising diffusion imaging sequence for the assessment of sinonasal lesions.

Publisher

SAGE Publications

Subject

Radiology, Nuclear Medicine and imaging,General Medicine,Radiological and Ultrasound Technology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3