Myocardial volume change during cardiac cycle derived from three orthogonal systolic strains: towards a quality assessment of strains

Author:

Bonnemains Laurent123ORCID,Guerard Anne Sophie23,Soulié Paul23,Odille Freddy234,Felblinger Jacques234

Affiliation:

1. Department of Cardiac Surgery, CHU Strasbourg, Strasbourg, France

2. U947, INSERM, Nancy, France

3. IADI, Université de Lorraine, Nancy, France

4. CIC-IT 1433, CHU Nancy, Nancy, France

Abstract

Background The relative modification of the myocardial volume between end-systole and end-diastole ([Formula: see text]) has already been assessed with different methods and falls in a range of 0.9–0.97 (mean value = 0.93). Purpose To estimate [Formula: see text] from the three longitudinal ([Formula: see text], circumferential ([Formula: see text]), and radial ([Formula: see text]) strains of the left ventricle using the formula: [Formula: see text] and to test whether this estimate of [Formula: see text] can be used as a marker of the echocardiography quality. Material and Methods Two hundred manuscripts, including a total of 34,690 patients or healthy volunteers, were identified in the Medline database containing values of [Formula: see text], [Formula: see text], and [Formula: see text] measured from echocardiography. Results The median value of was 0.93, in accordance with the literature, with no significant difference between patients or healthy volunteers ( P = 0.38). The proportion of studies with [Formula: see text] was 79%. When only considering groups of healthy volunteers, the studies failing this test had higher standard deviations for the three individual strains: 0.038 vs. 0.029 ( P = 0.02) for [Formula: see text]; 0.060 vs. 0.034 ( P < 10–6) for [Formula: see text], and 0.243 vs. 0.101 ( P < 10–14) for [Formula: see text]. Conclusion The median ratio of the left ventricular myocardial volumes between end-systole and end-diastole in the investigated studies was [Formula: see text]. The formula [Formula: see text] could be used to detect studies with inaccurate strain measurements.

Publisher

SAGE Publications

Subject

Radiology Nuclear Medicine and imaging,General Medicine,Radiological and Ultrasound Technology

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3