MRI reliability in pediatric abdominal lymph node metastases?

Author:

Gülçin Bozbeyoğlu Sabriye1ORCID,Perçem Orhan Söylemez Umut1,Gündüz Nesrin2ORCID

Affiliation:

1. Department of Radiology, Istanbul Goztepe Prof Dr Suleyman Yalcin City Hospital, Kadıköy, Turkey

2. Department of Radiology, Faculty of Medicine, Goztepe Prof. Dr. Suleyman Yalcin City Hospital, Istanbul Medeniyet University, Istanbul, Turkey

Abstract

Background Although positron emission tomography-computed tomography (PET-CT) is an effective imaging method used in the detection of lymph node metastases, repeated imaging increases X-ray exposure, especially in pediatric patients. Magnetic resonance imaging (MRI) may detect abdominal lymph nodes and provide subtle anatomic detail, and functional information without radiation. Purpose To evaluate the reliability of MRI in detecting lymph node metastases in pediatric abdominal malignancies and to determine whether X-ray dose can be reduced by comparing its effectiveness with PET-CT. Material and Methods Patients aged <18 years, diagnosed with abdominal malignant solid lesions between January 2015 and 2022 were included in this retrospective single-center study. A total of 14 A total of 14 different anatomic locations were defined for lymph nodes in MRI and PET-CT examinations. Cohen's kappa test was used to evaluate the consistency between PET-CT and MRI. P < 0.05 was considered statistically significant. Results In total, 25 patients (18 [72%] girls, 7 [28%] boys; mean age = 9.32 ± 16.9 years; age range = 1–18 years) with abdominal solid malignant tumors were included. The reliability of MRI and inter-observer reliability differed depending on the location of the lymph nodes. The reliability was almost perfect for the internal iliac (k = 0.915), porta hepatis, and aortocaval lymph node stations, while fair reliability was observed for the mesenteric lymph nodes (k = 0.525). Conclusion The results showed that MRI was as reliable as PET-CT in detecting some intra-abdominal metastatic lymph nodes, while its reliability was lower in some lymph node stations.

Publisher

SAGE Publications

Subject

Radiology, Nuclear Medicine and imaging,General Medicine,Radiological and Ultrasound Technology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3