Abstract

Background Avascular osteonecrosis of the femoral head (AVN) often results in total hip arthroplasty (THA). The cause for increased THA revision rates among patients with AVN is not yet fully understood. Purpose To perform a comparative radiological analysis of implant integration between patients with AVN and osteoarthritis (OA). Material and Methods After a matched pair analysis of 58 patients, 30 received THA due to OA, 28 due to AVN. X-ray images were evaluated after one week (“baseline”) and on average 37.58 months postoperatively (“endline”). The prosthesis was grouped into 10 regions of interest (ROI): seven femoral and three acetabular. Incidence, width, and extent of “radiolucent lines” were measured within each zone. Results Between baseline and endline, width and extent progressed more noticeably in all femoral and acetabular zones among patients with AVN. In femoral ROI 1, the width increased in 40% of AVN cases compared to 6.7% of OA cases. For acetabular ROI 3, the width increased in 26.7% of AVN cases compared to no perceived changes in the OA group. No signs of prosthetic loosening were found in the AVN group. Conclusion The increase of width and extent of radiolucent lines over time in patients with AVN could be a sign of lack of osteointegration. However, prosthetic loosening in absence of clinical symptoms cannot be deduced from radiological findings after medium-term postoperative follow-up. Further long-term studies are required to monitor how radiolucent lines develop in respect to long-term implant loosening. Dependent on bone quality, individually adapted reaming and broaching of the implant site are recommended.

Publisher

SAGE Publications

Subject

Radiology, Nuclear Medicine and imaging,General Medicine,Radiological and Ultrasound Technology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3