Affiliation:
1. Department of Diagnostic and Interventional Radiology, University Hospital Heidelberg, Heidelberg, Germany
2. Department of Radiology and Nuclear Medicine, University Hospital Basel, Basel, Switzerland
3. Department of Cardiothoracic Surgery, University Hospital Heidelberg, Heidelberg, Germany
Abstract
Background There is a high probability for presence of irregular heart rates and artifacts in patients with previous coronary artery bypass graft (CABG) surgery. Previously reported diagnostic performance of ECG-gated 64-slice dual-source computer tomography angiography (CTA) in this patient group is based on pre-selection for normal heart rate and routine clinical setting. Purpose To investigate image quality and diagnostic performance of CTA in patients with previous CABG surgery in various clinical settings. Material and Methods Fifty-six non-selected, consecutive patients (110 grafts, 44 arterial, 66 venous) with previous CABG surgery were prospectively examined using a dual-source 64-slice CT (Siemens Definition, Forchheim, Germany) without utilization of CT-related pharmaceutical heart rate control. Patients were stratified according to the clinical setting: planned redo-cardiac surgery; emergency CTA within 30 days after CABG surgery; routine follow-up after CABG surgery. A reference standard was available for 30 patients (53.6%; 67/110 grafts). Image quality, artifacts, and graft patency were independently assessed by two observers. Results All CTAs were diagnostic despite the presence of irregular heart rhythm (25% of cases) and artifacts (72.7% of grafts). CTA was accurate in all patient groups in assessing graft patency (97.9% sensitivity; 100% specificity; 98.5% accuracy) but artifacts decreased diagnostic performance for stenosis detection (60% sensitivity; 88.6% specificity; 84.1% accuracy). Arterial grafts exhibited more surgical clip artifacts compared to venous grafts, which predominantly showed motion artifacts. Overall diagnostic quality was rated excellent in 70.9%/56.4%, good in 23.4%/39.1%, and sufficient in 5.5%/4.5% by each observer, respectively. CTA detected acute findings in 10 cases (graft bleeding, graft occlusion, pericardial hematoma, sternal instability with retrosternal abscess formation, pericardial effusion, left ventricle thrombus) in the emergency group; seven cases required surgical revision. Conclusion Dual-source CTA is a robust and accurate method for assessment of graft patency and detection of relevant extra-cardiac pathologies in a non-selected patient population after CABG surgery in routine as well as emergency clinical settings. Artifacts caused by irregular heart rhythm or surgical clips do not impair graft patency evaluation but limit stenosis assessment.
Subject
Radiology, Nuclear Medicine and imaging,General Medicine,Radiological and Ultrasound Technology
Cited by
12 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献