Computed tomography angiography of coronary artery bypass grafts: robustness in emergency and clinical routine settings

Author:

Heye Tobias12,Kauczor Hans-Ulrich1,Szabo Gabor3,Hosch Waldemar1

Affiliation:

1. Department of Diagnostic and Interventional Radiology, University Hospital Heidelberg, Heidelberg, Germany

2. Department of Radiology and Nuclear Medicine, University Hospital Basel, Basel, Switzerland

3. Department of Cardiothoracic Surgery, University Hospital Heidelberg, Heidelberg, Germany

Abstract

Background There is a high probability for presence of irregular heart rates and artifacts in patients with previous coronary artery bypass graft (CABG) surgery. Previously reported diagnostic performance of ECG-gated 64-slice dual-source computer tomography angiography (CTA) in this patient group is based on pre-selection for normal heart rate and routine clinical setting. Purpose To investigate image quality and diagnostic performance of CTA in patients with previous CABG surgery in various clinical settings. Material and Methods Fifty-six non-selected, consecutive patients (110 grafts, 44 arterial, 66 venous) with previous CABG surgery were prospectively examined using a dual-source 64-slice CT (Siemens Definition, Forchheim, Germany) without utilization of CT-related pharmaceutical heart rate control. Patients were stratified according to the clinical setting: planned redo-cardiac surgery; emergency CTA within 30 days after CABG surgery; routine follow-up after CABG surgery. A reference standard was available for 30 patients (53.6%; 67/110 grafts). Image quality, artifacts, and graft patency were independently assessed by two observers. Results All CTAs were diagnostic despite the presence of irregular heart rhythm (25% of cases) and artifacts (72.7% of grafts). CTA was accurate in all patient groups in assessing graft patency (97.9% sensitivity; 100% specificity; 98.5% accuracy) but artifacts decreased diagnostic performance for stenosis detection (60% sensitivity; 88.6% specificity; 84.1% accuracy). Arterial grafts exhibited more surgical clip artifacts compared to venous grafts, which predominantly showed motion artifacts. Overall diagnostic quality was rated excellent in 70.9%/56.4%, good in 23.4%/39.1%, and sufficient in 5.5%/4.5% by each observer, respectively. CTA detected acute findings in 10 cases (graft bleeding, graft occlusion, pericardial hematoma, sternal instability with retrosternal abscess formation, pericardial effusion, left ventricle thrombus) in the emergency group; seven cases required surgical revision. Conclusion Dual-source CTA is a robust and accurate method for assessment of graft patency and detection of relevant extra-cardiac pathologies in a non-selected patient population after CABG surgery in routine as well as emergency clinical settings. Artifacts caused by irregular heart rhythm or surgical clips do not impair graft patency evaluation but limit stenosis assessment.

Publisher

SAGE Publications

Subject

Radiology, Nuclear Medicine and imaging,General Medicine,Radiological and Ultrasound Technology

Cited by 10 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. CAD-RADS: Pushing the Limits;RadioGraphics;2020-05

2. Coronary Artery Bypass Graft Imaging and Assessment of Flow;Cardiovascular Magnetic Resonance;2019

3. Cardiac Computed Tomography;Journal of Thoracic Imaging;2018-05

4. CT and MRI;Chronic Coronary Artery Disease;2018

5. CT angio for the evaluation of graft patency;Journal of Thoracic Disease;2017-04

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3