Influence of contrast agent on artificial intelligence-based CT low attenuation volume percentage measurement

Author:

Wiedbrauck Damian12,Karczewski Maciej3,Schoenberg Stefan O2,Fink Christian12,Kayed Hany2ORCID

Affiliation:

1. Department of Radiology, AKH Celle, Celle, Germany

2. Department of Clinical Radiology and Nuclear Medicine, Medical Faculty Mannheim, University Medical Centre Mannheim, University of Heidelberg, Mannheim, Germany

3. Department of Applied Mathematics, Wrocław University of Environmental and Life Sciences, Wroclaw, Poland

Abstract

Background Low attenuation volume percentage (LAV%) has been identified as a quantitative imaging biomarker for emphysema with good correlation with spirometry. The influence of intravenous contrast agent on LAV% and its correlation with spirometry is not well known. Purpose To evaluate the influence of intravenous contrast agent on artificial intelligence (AI)-based LAV% in correlation with spirometric Tiffeneau-Pinelli Index (TI). Material and Methods In a retrospective study, two groups of 47 patients (mean age 68.04 ± 12.64 and 67.89 ± 11.54 years) with either non-enhanced chest computed tomography (CT) or contrast-enhanced CT were compared. Using an AI-based software, LAV% was quantified using a threshold <−950 HU. TI was calculated from spirometry and pathologic airway obstruction was considered with a TI <70. The effect of contrast agent on LAV% and the relationship between TI and LAV% was analyzed. Correlation coefficients between TI and LAV% were compared for both groups. Results Patients with non-enhanced CT had a mean LAV% of 9.07 ± 7.53. Of them, 22 patients had a TI <70% and 25 patients a TI ≥70%. Patients with contrast-enhanced CT had a mean LAV% of 6.54 ± 4.62. Of them, 20 patients had a TI <70% and 27 patients had a TI ≥70%. Contrast agent did not show a major effect on LAV% ( P = 0.099) and the relationship between TI and LAV% ( P = 0.88). In both groups, a significant correlation between TI and LAV% was found (ρ = −0.317 for non-enhanced CT; ρ = −0.514 for contrast-enhanced CT). Difference between correlation coefficients was insignificant. Conclusion Our findings suggest that contrast agent does not influence LAV% nor its correlation with TI.

Publisher

SAGE Publications

Subject

Radiology, Nuclear Medicine and imaging,General Medicine,Radiological and Ultrasound Technology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3