Optimal detection of scapholunate ligament tears with MRI

Author:

Greditzer Harry G1,Zeidenberg Joshua2,Kam Check C3,Gray Robert R3,Clifford Paul D2,Mintz Douglas N1,Jose Jean2

Affiliation:

1. Department of Radiology & Imaging/Hospital for Special Surgery, New York, New York, USA

2. Department of Radiology, University of Miami/Jackson Memorial Hospital, Miami, Florida, USA

3. Department of Orthopaedic Surgery, University of Miami/Jackson Memorial Hospital, Miami, Florida, USA

Abstract

Background Scapholunate interosseous ligament (SLIL) injuries can often be difficult to detect using magnetic resonance imaging (MRI), especially with older 1.0 and 1.5 Tesla magnets. Wrist arthroscopy is the gold standard for diagnosis of SLIL injuries, but is an invasive procedure with associated risks. Purpose To assess whether SLIL injuries can be more accurately detected using axial MRI sequences instead of coronal sequences. Material and Methods An institutional review board approved retrospective analysis of arthroscopic wrist surgeries performed at our institution. Patients that had a preoperative MRI performed at our university center using a 1.5 Tesla scanner with a dedicated wrist coil were included in the study. Three fellowship-trained musculoskeletal radiologists reviewed the axial sequences and coronal sequences independently. The accuracy of the coronal and axial sequences was compared with the arthroscopic/surgical findings. Result Twenty-six patients met the inclusion criteria. The sensitivity for SLIL tears was 79% and 65% for the axial and coronal sequences, respectively. The specificity was 82% for the axial and 69% for the coronal sequences, respectively. The positive and negative predictive values for the axial sequences were 76% and 84% respectively, compared to 68% and 71% for the coronal sequences, a statistically significant difference. Conclusion SLIL tears are more readily detectable on axial MRI sequences than coronal. Clinically, patients with radial-sided wrist pain and suspicion for SLIL tears should have the axial sequences scrutinized carefully. An otherwise normal study with the axial sequence being degraded by motion or other MRI artifacts might need repeat imaging.

Publisher

SAGE Publications

Subject

Radiology, Nuclear Medicine and imaging,General Medicine,Radiological and Ultrasound Technology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3