Hemodialysis clearance of iosimenol, a novel iso-osmolar radiographic contrast medium

Author:

Hirao Yukihiro1,Kashiyama Eiji1,Umehara Ken1,Kohno Makoto2,Ikei Nobuhiro3,Hogstrom Barry4

Affiliation:

1. Tokushima Research Institute, Otsuka Pharmaceutical Co., Ltd., Tokushima, Japan

2. Department of Bio Research, Kamakura Techno-Science, Inc., Kanagawa, Japan

3. Otsuka International Asia Arab Division, Otsuka Pharmaceutical Co., Ltd., Osaka, Japan

4. Otsuka Novel Product, Medical Imaging, Otsuka Pharmaceutical Development & Commercialization, Inc., Princeton, NJ, USA

Abstract

Background Iodinated contrast media (CM) have molecular and pharmacokinetic properties likely to make them highly dialyzable. Controlled clinical studies allowing for comparisons of hemodialysis clearance between different test substances and in multiple hemodialysis filters are, however, complex and not always practically feasible. A miniaturized in vitro method was therefore developed to evaluate the dialyzability of a new CM. Purpose To evaluate hemodialysis clearance of iosimenol, a novel iso-osmolar contrast medium (CM), in a select variety of hemodialysis filters and in comparison to commercially available CM. Material and Methods Three different high-flux and one low-flux membrane were used in miniaturized dialyzers to evaluate the in vitro blood clearance of iosimenol. Commercially available CM (iodixanol and iohexol) served as control substances. In vitro dialysis parameters were then used to predict clinical hemodialysis clearances. Residual ratios of endogenous substances (inorganic phosphate, urea nitrogen, creatinine, total bilirubin, and albumin) were used as proof of reliability of the in vitro dialysis system. Results Dialyzable small endogenous molecules were readily eliminated in all membranes. The removal ratios of iosimenol were generally similar to that of iodixanol in all membranes except the high-flux polysulfone but were consistently lower than that of iohexol. The blood clearance of iosimenol during clinical hemodialysis was predicted as, on average, approximately 85 mL/min with the high-flux membranes and 47 mL/min with the low-flux membrane. Conclusion The dialyzability of iosimenol was evaluated using a newly developed in vitro dialysis system, and iosimenol was readily cleared from blood with all four tested membranes. And it is suggested that the dialysis parameters can predict clinical hemodialysis clearance of CM.

Publisher

SAGE Publications

Subject

Radiology Nuclear Medicine and imaging,General Medicine,Radiological and Ultrasound Technology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3