Reproducibility for carotid wall segmentation using T1-weighted DANTE-SPACE sequence on high-resolution 3-T carotid MRI

Author:

Won So Yeon12ORCID,Lee Kijeong23,Shin Ilah24,Choi Hyun Seok245,Choi Jai Ho6,Kim Bum-Soo4ORCID,Shin Yong Sam6

Affiliation:

1. Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea

2. Department of Radiology and Research Institute of Radiological Science and Center for Clinical Imaging Data Science, Yonsei University College of Medicine, Seoul, Republic of Korea

3. Department of Neurology, College of Medicine, Seoul St. Mary’s Hospital, The Catholic University of Korea, Seoul, Republic of Korea

4. Department of Radiology, College of Medicine, Seoul St. Mary’s Hospital, The Catholic University of Korea, Seoul, Republic of Korea

5. Department of Radiology, Seoul Medical Center, Seoul, Republic of Korea

6. Department of Neurosurgery, College of Medicine, Seoul St. Mary’s Hospital, The Catholic University of Korea, Seoul, Republic of Korea

Abstract

Background T1-weighted (T1W) magnetic resonance imaging (MRI) using the delay alternating with nutation for excitation-sampling perfection with application-optimized contrasts using different flip angle evolution (DANTE-SPACE) is the preferred imaging technique for evaluation of the vessel wall. Purpose To evaluate the intra- and inter-rater reproducibility of carotid wall segmentation on T1W DANTE-SPACE in patients with symptomatic (acute stroke or transient ischemic attack) internal carotid artery (ICA) stenosis. Material and Methods This prospective study included 25 patients with acute (≤3 months) stroke or transient ischemic attack and 50%–99% stenosis of the ICA. All patients underwent 3.0-T high-resolution carotid MRI. Two radiologists independently performed the manual segmentation of the vessel wall and inner lumen of the bilateral carotid artery on DANTE-SPACE. The intraclass correlation coefficient (ICC), Dice similarity coefficient (DSC), and Hausdorff distance (HD) were calculated. Results The ICCs for intra-rater reproducibility of carotid wall volume, inner lumen volume, and normalized wall index were 0.965, 0.990, and 0.962, respectively. The ICCs for inter-rater reproducibility of carotid wall volume, inner lumen, and normalized wall index were 0.856, 0.981, and 0.904. DSC and HD for intra- and inter-rater reproducibility of carotid wall segmentation were as follows: 0.873 and 0.809 (DSC); and 0.079 and 0.118 (HD), respectively. For evaluation of reproducibility only in the carotid artery with symptomatic stenosis, the ICCs for intra- and inter-rater reproducibility indicated all perfect agreement. Conclusion T1W DANTE-SPACE is a reproducible sequence for evaluation of the carotid wall using carotid MRI in patients with symptomatic ICA stenosis.

Funder

Ministry of Science and ICT, South Korea

Bayer Korea

Publisher

SAGE Publications

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3