Levels of agreement between cardiac magnetic resonance and conductance catheter measurements of right ventricular volumes after pulmonary artery banding

Author:

Gufler Hubert12ORCID,Wagner Sabine1,Niefeldt Sabine3,Klopsch Christian3,Brill Richard2,Wohlgemuth Walter Alexander2,Yerebakan Can3

Affiliation:

1. Department of Diagnostic and Interventional Radiology, University Clinic, Rostock, Germany

2. Clinic and Policlinic of Diagnostic Radiology, Martin-Luther University Halle-Wittenberg, 01620, Germany

3. Department of Cardiac Surgery, University Clinic, Rostock, Germany*Equal contributors.

Abstract

Background Pressure-volume analysis is the gold standard for quantifying pump function of the right ventricle (RV); however, volume measurements based on a conductive catheter may be imprecise. The reference method for volume assessment is cardiac magnetic resonance (CMR). Purpose To determine the levels of agreement between RV volume measurements obtained by cine CMR, phase-contrast CMR (PC CMR), and a conductance catheter in an animal model. Material and Methods CMR was performed in 20 sheep three months after pulmonary artery banding. Ejection fraction (EF), end-diastolic (EDV), end-systolic (ESV), and stroke volumes (SV) were obtained by cine CMR and conductance catheter. Results Statistically significant differences between cine CMR and conductance catheter derived volume measurements were found for EDV ( P < 0.001), ESV ( P < 0.05), and SV ( P < 0.05). Bland–Altman analysis showed very poor agreement between the two methods: EDV, bias 36.27 mL, agreement of limits 1.96–70.57 mL; ESV, bias 15.33 mL, agreement of limits –6.89–37.55 mL; and SV, bias 20.69 mL, agreement of limits 8.01–49.10 mL. Good agreement was found for SV between cine CMR and PC CMR (bias –7.0 mL, agreement of limits –24.01–9.98 mL), while SV derived from PC CMR measurements showed poor agreement with conductance catheter (bias 27.76 mL, agreement of limits –3.84–59.26 mL). Conclusion Poor agreement between the conductance catheter and CMR RV volume measurements was found. PC CMR and cine CMR measurements of SV agreed well.

Publisher

SAGE Publications

Subject

Radiology Nuclear Medicine and imaging,General Medicine,Radiological and Ultrasound Technology

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3