CT chest and gantry rotation time: does the rotation time influence image quality?

Author:

Beeres Martin1,Wichmann Julian L1,Paul Jijo1,Mbalisike Emmanuel1,Elsabaie Mohamed1,Vogl Thomas J1,Nour-Eldin Nour-Eldin A12

Affiliation:

1. Department of Diagnostic and Interventional Radiology, Clinic of the Goethe University, Frankfurt, Germany

2. Diagnostic and Interventional Radiology Department, Cairo University Hospital, Cairo, Egypt

Abstract

Background Computed tomography (CT) gantry rotation time is one factor influencing image quality. Until now, there has been no report investigating the influence of gantry rotation time on chest CT image quality. Purpose To investigate the influence of faster gantry rotation time on image quality and subjective and objective image parameters in chest CT imaging. Material and Methods Chest CT scans from 160 patients were examined in this study. All scans were performed using a single-source mode (collimation, 128 × 0.6 mm; pitch, 1.2) on a dual-source CT scanner. Only gantry rotation time was modified, while other CT parameters were kept stable for each scan (120 kV/110 reference mAs). Patients were divided into four groups based on rotation time: group 1, 1 s/ rotation (rot); group 2, 0.5 s/rot; group 3, 0.33 s/rot; group 4, 0.28 s/rot. Two blinded radiologists subjectively compared CT image quality, noise, and artifacts, as well as radiation exposure, from all groups. For objective comparison, all image datasets were analyzed by a radiologist with 5 years of experience concerning objective measurements as well as signal-to-noise ratio (SNR). Results We found that faster gantry rotation times (0.28 s/rot and 0.33 s/rot) resulted in more streak artifacts, image noise, and decreased image quality. However, there was no significant difference in radiation exposure between faster and slower rotation times ( P > 0.7). Conclusion Faster CT gantry rotation reduces scan time and motion artifacts. However, accelerating rotation time increases image noise and streak artifacts. Therefore, a slower CT gantry rotation speed is still recommended for higher image quality in some cases.

Publisher

SAGE Publications

Subject

Radiology Nuclear Medicine and imaging,General Medicine,Radiological and Ultrasound Technology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3