Image quality of low-radiation dose left atrial CT using filtered back projection and an iterative reconstruction algorithm: intra-individual comparison in unselected patients undergoing pulmonary vein isolation

Author:

Fahlenkamp Ute Lina1,Diaz Ramirez Ivan2,Wagner Moritz1,Schwenke Carsten3,Huppertz Alexander14,Hamm Bernd1,Lembcke Alexander1

Affiliation:

1. Department of Radiology, Charité – Universitätsmedizin Berlin, Berlin, Germany

2. Department of Cardiology, Charité – Universitätsmedizin, Berlin, Germany

3. SCO:SSiS, Statistical Consulting, Berlin, Germany

4. Present address: Klinikum Ernst von Bergmann, Potsdam, Germany

Abstract

Background Computed tomography (CT) of the left atrium (LA) is performed prior to pulmonary vein isolation (PVI) to improve success of circumferential ablation for atrial fibrillation. The ablation procedure itself exposes patients to substantial radiation doses, therefore radiation dose reduction in pre-ablational imaging is of concern. Purpose To assess and compare diagnostic performance of low-radiation dose preprocedural CT in patients scheduled for PVI using two types of reconstruction algorithms. Material and Methods Forty-six patients (61 ± 10 years) scheduled for PVI were enrolled in this study irrespective of body-mass-index or cardiac rhythm at examination. An electrocardiographically triggered dual-source CT scan was performed. Filtered back projection (FBP) and iterative reconstruction (IR) algorithms were applied. Images were integrated into an electroanatomic mapping (EAM) system. Subjective image quality was scored independently by two readers on a five-point scale for both reconstruction algorithms (1 = excellent to 5 = non-diagnostic). Signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and effective radiation dose were calculated. Results Data acquisition and EAM integration were successful in all patients. Median image quality score was 1 for both FBP (quartiles = 1, 1.62; range = 1–3) and IR (quartiles = 1, 1.5; range = 1–3). Mean SNR was 7.61 ± 2.14 for FBP and 9.02 ± 2.69 for IR. Mean CNR was 5.92 ± 1.80 for FBP and 6.95 ± 2.29 for IR. Mean effective radiation dose was 0.3 ± 0.1 mSv. Conclusion At a radiation dose of 0.3 ± 0.1 mSv, high-pitch dual-source CT yields LA images of consistently high quality using both FBP and IR. IR raises SNR and CNR without significantly improving subjective image quality.

Publisher

SAGE Publications

Subject

Radiology Nuclear Medicine and imaging,General Medicine,Radiological and Ultrasound Technology

Reference25 articles.

1. Spontaneous Initiation of Atrial Fibrillation by Ectopic Beats Originating in the Pulmonary Veins

2. 2012 HRS/EHRA/ECAS Expert Consensus Statement on Catheter and Surgical Ablation of Atrial Fibrillation: Recommendations for Patient Selection, Procedural Techniques, Patient Management and Follow-up, Definitions, Endpoints, and Research Trial Design: A report of the Heart Rhythm Society (HRS) Task Force on Catheter and Surgical Ablation of Atrial Fibrillation. Developed in partnership with the European Heart Rhythm Association (EHRA), a registered branch of the European Society of Cardiology (ESC) and the European Cardiac Arrhythmia Society (ECAS); and in collaboration with the American College of Cardiology (ACC), American Heart Association (AHA), the Asia Pacific Heart Rhythm Society (APHRS), and the Society of Thoracic Surgeons (STS). Endorsed by the governing bodies of the American College of Cardiology Foundation, the American Heart Association, the European Cardiac Arrhythmia Society, the European Heart Rhythm Association, the Society of Thoracic Surgeons, the Asia Pacific Heart Rhythm Society, and the Heart Rhythm Society

3. Initial Experience in the Use of Integrated Electroanatomic Mapping with Three-Dimensional MR/CT Images to Guide Catheter Ablation of Atrial Fibrillation

4. The Impact of CT Image Integration into an Electroanatomic Mapping System on Clinical Outcomes of Catheter Ablation of Atrial Fibrillation

5. Imaging of pulmonary vein anatomy using low-dose prospective ECG-triggered dual-source computed tomography

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3