Differences in cerebral blood flow measurement using arterial spin labeling MRI between patients with moyamoya disease and patients with arteriosclerotic cerebrovascular disease

Author:

Ueda Yasuhiro1ORCID,Tanaka Yoji1ORCID,Hara Shoko12ORCID,Inaji Motoki12,Ishii Kenji2,Maehara Taketoshi1,Nariai Tadashi12

Affiliation:

1. Department of Neurosurgery, Tokyo Medical and Dental University, Tokyo, Japan

2. Research Team for Neuroimaging, Tokyo Metropolitan Institute of Gerontology, Tokyo, Japan

Abstract

Background It is unclear whether the accuracy of arterial spin labeling (ASL) magnetic resonance imaging (MRI) is the same between moyamoya disease (MMD), which is known to have markedly elevated cerebral blood volume (CBV), and atherosclerotic intracranial arterial stenosis (AS), which has relatively less elevated CBV. Purpose To investigate how the differences in hemodynamics affect measurement of ASL-cerebral blood flow (CBF) using ASL for patients with MMD and AS. Material and Methods Fourteen MMD and ten AS patients were evaluated with ASL-MRI, magnetic resonance angiography (MRA), and 15O-gas positron emission computed tomography (PET). The regional CBF values of ASL using two post-labeling delays (PLDs; 1525 ms and 2525 ms) were compared with the PET-derived CBF, CBV, and mean transit time (MTT). Corresponding anterior circulation results were evaluated by flow territory map-based analysis. Results The correlation between the ASL-CBF values (2525 ms) and PET-CBF declined in the MMD group (r = 0.28; P < 0.01), while the AS group showed good correlation (r = 0.77; P < 0.01). In the MMD group, the ASL-CBF values (2525 ms) overestimated the PET-CBF values as the regional CBV values increased (r = 0.35; P < 0.01). When the regions of interest were divided into two subgroups according to the degree of arterial stenosis by MRA, the correlation coefficient between the ASL-CBF (2525 ms) and PET-CBF values improved (mild stenosis: r = 0.36; P = 0.06; severe stenosis: r = 0.51; P < 0.01). Conclusion The accuracy of CBF measurements using ASL-MRI differed between patients with MMD and AS. The prominent increase of CBV and the degree of arterial stenosis may have affected the accuracy of ASL-CBF in patients with MMD.

Publisher

SAGE Publications

Subject

Radiology, Nuclear Medicine and imaging,General Medicine,Radiological and Ultrasound Technology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3