Warmed contrast media temperature loss in traditional manifold systems during angiographic procedures

Author:

O'Sullivan Kevin J.12,Kermavnar Tjaša1,Gorski Kenneth A.3,Arnous Samer4,O'Sullivan Leonard W.12ORCID

Affiliation:

1. School of Design and Confirm Smart Manufacturing Centre, University of Limerick, Limerick, Ireland

2. Health Research Institute, School of Design and Confirm Smart Manufacturing Centre, University of Limerick, Limerick, Ireland

3. Aultman Deuble Heart and Vascular Hospital, Canton, OH, USA

4. University Hospital Limerick, Limerick, Ireland

Abstract

Background Extrinsic warming of contrast media (CM) to 37 °C before angiographic procedures is performed to improve bolus kinetics and avoid potential adverse effects. Extrinsically warmed CM readily loses temperature after removal from the warming cabinet, but the extent of its cooling has not been previously investigated. Purpose To assess temperature loss of extrinsically warmed CM in tubing of traditional angiographic manifolds during simulated angiography. Material and Methods In total, 35 scheduled diagnostic angiographic procedures were observed in a hospital setting. Relevant time points of CM use during the procedures were recorded. The shortest, median, and longest procedures were then simulated in the experimental laboratory to measure CM temperatures at specific times at three locations along the tubing system. Results The angiographic procedures lasted 7.0–26.6 min (median = 11.7 min), with the total duration dependent primarily on the time from contrast being removed from the warming cabinet to the commencement of imaging. During the simulated procedures, consistent patterns of temperature loss were observed. By the last simulated angiographic run, injected CM temperature decreased by 7.4–16.4 °C, depending on procedure length. Most of the heat loss occurred in the tubing between the CM bottle and coronary control syringe. Conclusion During angiographic procedures, prewarmed CM loses its temperature rapidly with the duration of exposure to ambient room temperature. If no additional measures are employed to maintain its temperature outside of the warming cabinet, extrinsic warming has limited impact on injected CM temperature.

Funder

Science Foundation Ireland

Publisher

SAGE Publications

Subject

Radiology, Nuclear Medicine and imaging,General Medicine,Radiological and Ultrasound Technology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3