Effect of image quality on myocardial extracellular volume quantification using cardiac computed tomography: a phantom study

Author:

Funama Yoshinori1ORCID,Oda Seitaro2,Kidoh Masafumi2,Sakabe Daisuke3,Nakaura Takeshi2

Affiliation:

1. Department of Medical Radiation Sciences, Faculty of Life Sciences, Kumamoto University, Kumamoto, Japan

2. Department of Diagnostic Radiology, Faculty of Life Sciences, Kumamoto University, Kumamoto, Japan

3. Department of Radiology, Kumamoto University Hospital, Kumamoto, Japan

Abstract

Background The image quality directly affects the accuracy of computed tomography (CT) extracellular volume (ECV) quantification. Purpose To investigate the effects of image quality and acquisition protocol on the accuracy of ECV quantification. Material and Methods One-volume scans were performed on a 320-row multidetector CT volume scanner using a multi-energy CT phantom. To simulate the blood pool and myocardium, solid rods representing blood and soft tissue were used in precontrast CT. Moreover, the solid rods including different iodine concentrations were used in postcontrast CT. The tube voltage was set at 120 kVp, and the tube current was changed from 750 mA (100% dose) to 190 mA (25% dose). All images underwent full- and half-scan reconstructions based on model-based iterative reconstruction. The ECV was calculated from the CT numbers between pre- and postcontrast. Results The mean ECV with full- and half-scan reconstructions at the central portion was 0.275 at 100% scan dose to 0.271 at 25% scan dose and 0.276 at 100% scan dose to 0.269 at 25% scan dose. Compared with that in the 100% scan dose, the variation in each ECV increased with decreasing radiation dose. The ECV at the center of the image along the z-axis had lower variation than that at outer portion of the images. On the reconstruction algorithm, there was no statistical difference in ECVs with full- and half-scan reconstructions. Conclusion For stable ECV quantifications, excessive radiation dose reduction may be inappropriate, and it is better to consider the variations in ECV values depending on the slice location.

Publisher

SAGE Publications

Subject

Radiology, Nuclear Medicine and imaging,General Medicine,Radiological and Ultrasound Technology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3