Reference ranges of fetal cisterna magna volume measurements by three-dimensional ultrasonography in the late second trimester considering sonographic experience

Author:

Selcuk Koray1,Sezik Mekin2ORCID,Yalcin Serenat Eris3,Yavuz And2

Affiliation:

1. Kastamonu Tosya State Hospital, Kastamonu, Turkey

2. Department of Obstetrics and Gynecology, Süleyman Demirel University Faculty of Medicine, Isparta, Turkey

3. Department of Obstetrics and Gynecology, University of Health Sciences Antalya Training and Research Hospital, Antalya, Turkey

Abstract

Background Volume measurements of fetal cisterna magna (CM) by three-dimensional (3D) ultrasonography may have a role in the diagnosis of various posterior fossa abnormalities. Purpose To evaluate reference intervals and reliability of fetal CM volume values by virtual organ computer-aided analysis (VOCAL) in structurally normal fetuses, considering experience of evaluators. Material and Methods Three operators with different 3D sonography experience levels measured CM volumes of 100 structurally normal fetuses at 18–27 weeks of gestation. Reference intervals for CM volumes were generated. Intraclass correlation coefficients (ICC) were calculated. Results Mean fetal CM volume measurements by the three operators did not significantly ( P = 0.49, P = 0.22, and P = 0.17, respectively) change through 20–23 weeks of gestation. Moderate degrees of inter-observer reliability were found with an ICC of 0.69 between novice and intermediate-level, ICC of 0.74 between experienced and intermediate-level, and ICC of 0.78 between experienced and novice observer, respectively. The novice sonographer generally overestimated CM measurements. Intra-observer reliability was good (ICC=0.85). Conclusion A reference chart for fetal CM volume by VOCAL was formed, revealing uniform mean values of 20–23 weeks of gestation. The inter-observer reliability is moderate, and biases seem relatively common for all experience categories.

Funder

Süleyman Demirel Üniversitesi

Publisher

SAGE Publications

Subject

Radiology, Nuclear Medicine and imaging,General Medicine,Radiological and Ultrasound Technology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3