Abstract
The combined use of AMBER (Advanced Multiple Beam Equalization Radiography) and a digital storage phosphor (SP) radiography system was evaluated for chest radiography in a pilot study with 4 patients. Four image modes with different dose levels were compared: the SP in combination with an AMBER equalized exposure (SP/AMBER) and 3 nonequalized exposures with dose levels corresponding to the respective calculated AMBER lung dose (SP/lung field dose), the calculated AMBER mediastinal dose (SP/mediastinal dose) and the calculated AMBER average dose (SP/average dose). All image modes were matched for Hurter and Driffield characteristics and subjectively rated according to visibility of details. The improved signal-to-noise (S/N) ratio of SP/AMBER resulted in a better visualization of structures in the mediastinum and the basal lung where SP/lung field dose scored lowest. For the central lung no quality differences were seen between techniques. The compressed dynamic range of the SP/AMBER images was more easily displayed on the hard-copy film. The combination of AMBER with SP radiography promises to overcome the dynamic range limitations of digital displays while, at moderate doses, giving better S/N and image quality than standard SP technique.
Subject
Radiology, Nuclear Medicine and imaging,General Medicine,Radiological and Ultrasound Technology
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
1. The physics of computed radiography;Physics in Medicine and Biology;2002-11-20