Exploring the impact of excluding intrahepatic segmental vessels on liver stiffness measurement and advanced fibrosis diagnosis using magnetic resonance elastography

Author:

Kim Wook1,Hwang Jeong Ah1ORCID,Min Ji Hye1,Lee Sunyoung2,Lee Ji Eun3,Shin Jaeseung1,Jeong Woo Kyoung1ORCID

Affiliation:

1. Department of Radiology and Center for Imaging Sciences, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea

2. Department of Radiology and Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine, Seoul, Republic of Korea

3. Department of Radiology, Soonchunhyang University College of Medicine, Bucheon Hospital, Bucheon, Republic of Korea

Abstract

Background The impact of excluding intrahepatic segmental vessels from regions of interest (ROIs) on liver stiffness measurement (LSM) via magnetic resonance elastography (MRE) remains uncertain. Purpose To determine the effect of excluding intrahepatic segmental vessels from ROIs on LSM obtained from MRE. Material and Methods This retrospective analysis included 95 participants who underwent successful two-dimensional gradient recalled-echo MRE before hepatic tumor resection (n = 49) or living liver donation (n = 46). The conventional LSM was determined by manually drawing ROIs on the elastogram within the 95% confidence region, staying 1 cm within the liver capsule and excluding large hilar vessels, the gallbladder, hepatic lesions, and artifacts. In addition, the modified LSM was determined by excluding intrahepatic segmental vessels. LSMs obtained by the two methods were compared with paired sample signed-rank test. Diagnostic performance for advanced fibrosis was calculated and compared using McNemar's test and Delong's test. The stage of hepatic fibrosis was assessed using surgical specimens by the METAVIR system. Results The modified LSM was larger than the conventional LSM (2.4 kPa vs. 2.2 kPa in reader 1; 2.7 kPa vs. 2.4 kPa in reader 2; P < 0.001). The modified LSM showed superior sensitivity (0.841 vs. 0.659 in reader 1; 0.864 vs. 0.705 in reader 2; P < 0.05) and area under the curve (0.901 vs. 0.820 in reader 1; 0.912 vs. 0.843 in reader 2; P < 0.05) for detecting advanced fibrosis (≥F3) than conventional LSM. Conclusion The exclusion of intrahepatic segmental vessels from ROIs in MRE affected the LSM and enhanced diagnostic performance for advanced fibrosis.

Funder

National Research Foundation of Korea(NRF) grant funded by the Korea governmen

Publisher

SAGE Publications

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3