Reproducibility of radiomics features derived from intravoxel incoherent motion diffusion-weighted MRI of cervical cancer

Author:

Chen Hao1,He Yaoyao1ORCID,Zhao Cecheng2,Zheng Lili1,Pan Ning34,Qiu Jianfeng5,Zhang Zhaoxi1,Niu Xiaohui2,Yuan Zilong1

Affiliation:

1. Department of Radiology, Hubei Cancer Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, PR China

2. College of informatics, Huazhong Agricultural University, Wuhan, PR China

3. College of Biomedical Engineering, South Central University for Nationalities, Wuhan, PR China

4. Hubei Key Laboratory of Medical Information Analysis and Tumor Diagnosis & Treatment, Wuhan, PR China

5. Medical Engineering and Technology Center, Shandong First Medical University & Shandong Academy of Medical Sciences, Taian, PR China

Abstract

Background The reproducibility of intravoxel incoherent motion (IVIM)-based radiomics studies in humans has not been reported. Purpose To determine the inter- and intra-observer variability on the reproducibility of IVIM-based radiomics features in cervical cancer (CC). Material and Methods The IVIM images of 25 patients with CC were retrospectively collected. Based on the high-resolution T2-weighted images, the regions of interest (ROIs) were independently delineated twice in diffusion-weighted images at a b value of 1000 s/mm2 (interval time was one month) by two radiologists. This was done at the largest transversal cross-sections of the tumors. The ROI was subsequently used in apparent diffusion coefficient (ADC), true diffusion coefficient (D), pseudo-diffusion coefficient (D*), and perfusion fraction (f) maps derived from IVIM images. In total, 105 radiomics features were then finally extracted from the IVIM-derived maps. The inter- and intra-observer reproducibility of IVIM-derived features was then evaluated using the intraclass correlation coefficient. Results Inter- and intra-observer variability affected the reproducibility of radiomics features. D* map had 100% and 95% reproducible features, ADC map had 89% and 93%, D map had 97% and 86%, while f map had 54% and 62% reproducible features with good to excellent reliability in the intra-observer analysis. Similarly, D* map had 90% and 94%, ADC map had 85% and 70%, D map had 81% and 78%, while f map had 41% and 93% reproducible features with good to excellent reliability in the inter-observer analysis. Conclusion Inter- and intra-observer variability can affect radiomics analysis. Cognizant to this, multicenter studies should pay more attention to intra- and inter-observer variability.

Publisher

SAGE Publications

Subject

Radiology, Nuclear Medicine and imaging,General Medicine,Radiological and Ultrasound Technology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3